background image

Page 6

VERSASSAGE Jets -

 These jets may be adjusted to provide either a 

stationary, direct stream or, by positioning the nozzle to one side or the 

other, a rotating jet stream. 
The 

VERSASSAGE

 jets allow you to regulate the force of the massage. 

Rotate the fascia ring counter-clockwise to reduce the force, or 

clockwise to increase the force. Notice that turning off the flow to some 

jets increases the flow to the other jets. To avoid damage to your spa’s 

plumbing and components, do not turn off more than half of these jets at 

the same time.  For cleaning instructions, see the 

VERSASSAGE

 Jets 

Maintenance section.

ORBISSAGE Jets -

 This jet provides a unique, pulsating massage. The 

flow is adjustable in that it can be turned completely off or on (by 

rotating the jet faceplate). It is also interchangeable with the 

VERSASSAGE

 jet. For cleaning or replacement instructions see 

VERSASSAGE

 Jets in the Spa Care and Maintenance section. 

DIVERTER VALVES

The diverter valves on your spa allow you to direct the flow of water 

from the pumps to various combinations of jets. The functions of these 

diverter valves can best be learned by experimentation as follows:
Set all air controls to the “ON” position.
Turn on both pumps.
Turn the handle on 

each diverter valve and 

see which groups of 

jets are affected. (Note 

that you can adjust the 

diverter valves to any 

position between the 

two possible extremes to 

achieve the jet pressure 

that feels best to you.)

IMPORTANT: 

Your 

spa is not designed to provide full power to all jets when the diverter 

valves are in the “mid” position. However, with the diverter valve in this 

position, you may increase the power to selected jets by rotating the 

face of the 

ADAPTAFLO

 and 

ADAPTASSAGE

 jets to close the ones 

that are not in use.

TIP: 

Turn both pumps on and place the diverter valves to the “Mid-

Position”. Then experiment with each of the air controls to see their 

effect. 

VERSASSAGE

 Jet

ORBISSAGE

 Jet

Getting Started

ACQUARELLA

 WATERFALL VALVE

Your spa is equipped with the 

ACQUARELLA

 

waterfall feature. It is activated by turning on Jet 

Pump 2 (either low or high speed). The flow is 

regulated by turning the waterfall valve on the 

inside wall of the spa.

AIR CONTROLS

Each jet system has its own air control. These allow 

you to change the power of the jets by regulating the 

amount of air that is mixed with the water coming out 

of the jets. 

ATLAS

 

NECK JET VALVE

The 

CALDERA 

spas are equipped with 4 directional neck jets located 

in the EcstaSeat

. The flow of the neck jets is regulated by turning the 

ATLAS

 NeckJet valve on the inside wall of the spa.

CALDERA

 LOGO LIGHT

The 

CALDERA

 logo on the front of the spa illuminates an orange and 

gray color. These colors indicate the power and ready status of the spa 

without having to open the cover to look at the control panel.

Orange Indicator:

 The ORANGE indicator will light when the spa 

water temperature is within 1°C of the set temperature, and will turn 

off when the temperature is outside of that range. If you increase or 

decrease the temperature setting of the spa, the ready indicator will 

turn off until the water temperature reaches the acceptable range for 

the new temperature setting. A flashing ORANGE indicator means a 

problem may exists with the temperature sensor (see Troubleshooting 

section for more information).

Gray Indicator: 

The GRAY indicator is ‘on’ when the spa is properly 

supplied with power. It also provides a diagnostic function–a flashing 

GRAY indicator indicates that the heater high limit has tripped, meaning 

that either the spa water is above its acceptable temperature range, 

or a malfunction has occurred within the spa (such as low circulation 

due to clogged filters). An ‘off’ GRAY indicator means that there is a 

problem with the spa control box or the power supplied to the spa (see 

Troubleshooting section for more information).

QUICK START-UP INSTRUCTIONS

BEFORE YOU FILL YOUR SPA

Make sure your spa has been properly installed per all local codes, this 

includes the location of the spa, the foundation of the spa as well as 

the electrical installation of the spa. Installation instructions in the form 

of a Pre-Delivery Instruction booklet can be obtained from either your 

CALDERA

 dealer or online.

DO:

•  Know which water treatment system you will be using and make sure 

you have necessary chemicals available. Read all of the instructions 

that come with the system.

•  Have 

MONARCH

 

 5-way Test Strips Available.

•  Have pH/Alkalinity Up & Down available.
•  Know the "Hardness" of your water, contact your dealer to help you 

with this information. See Water Quality and Maintenance for more 

information.  

IMPORTANT:

 

WATKINS WELLNESS

 does not recommend that 

the spa be filled with “softened” water, as this may damage the spa’s 

equipment.

•  Purchase the Clean Screen

 pre-filter to remove unwanted 

contaminants from the tap water. This is recommended, not required.

DON'T:

•  Power up the spa until it has been filled with water!

 

Power to the 

spa automatically activates critical components within the spa, such 

as controls, heater, circulation pump, and other systems. If power 

is supplied to these components prior to the spa being filled, the 

components will be damaged, and this may result in a non-warranty 

component failure.

•  Fill the spa with hot water or cold water with cold water temperature 

below 10ºC (50ºF)! Tripping of the high-limit thermostat may result 

causing your spa to stop functioning.

START-UP

Your 

CALDERA

 spa has been thoroughly tested during the 

manufacturing process to ensure reliability and long-term customer 

satisfaction. A small amount of water may have remained in the 

plumbing after testing and, as a result, may have spotted the spa shell 

or the spa siding prior to delivery. Before filling the spa, wipe the spa 

shell clean with a soft rag. The following instructions must be read and 

followed exactly to ensure a successful start-up or refill.

CAUTIONS

•  DO NOT fill the spa with hot water, 

as tripping of the high-limit 

thermostat may result.

•  DO NOT CONNECT POWER TO AN EMPTY SPA. 

Power to the 

spa automatically activates critical components within the spa, such 

as controls, heater, and other systems. If power is supplied to these 

components prior to the spa being filled, the components will be 

damaged, and this may result in a non-warranty component failure.

•  DO NOT 

use your spa after filling until all of the steps listed below are 

completed.

•  DO NOT 

add chlorine if treating your spa with polyhexamethylene 

biguanide (Biguanide, PHMB, eg. 

BAQUASPA

) sanitizer.

•  Before filling your spa for the first time, remove the equipment 

compartment door and check to ensure that the unions on either side 

of the pump(s) and heater are hand-tight.  
1.  

CLOSE DRAIN, remove the filter compartment cover, skimmer 

basket, weir, and filter. 

Fill your spa through the filter compartment 

using the CleanScreen

 pre-filter that attaches to your garden hose. 

The water level of your spa should be maintained at a level 2.5 cm 

(1") above the highest jet in the shell of the spa. Reinstall the filter 

and then the skimmer basket, and weir once the spa is filled.   

Gray indicator - Power to spa is on

Orange indicator - water is ready, within 1°C of set temperature

Summary of Contents for UTOPIA CANTABRIA

Page 1: ...UTOPIA SERIES 2 0 1 8 O W N E R S M A N U A L 5 0 H z...

Page 2: ...SERIAL NUMBER ___________________________ COVER SERIAL NUMBER _______________________________ In most cities and counties permits will be required for the installation of electrical circuits or the co...

Page 3: ...EL 18 CANTABRIA ULTRAMASSEUSE CONTROL PANEL 18 JET MENU CANTABRIA 20 GENEVA 21 NIAGARA 22 TAHITIAN 23 FLORENCE 24 PROVENCE 25 SPA CARE AND MAINTENANCE FILTER MAINTENANCE 26 FILTER CARTRIDGE REMOVALAND...

Page 4: ...rated audio video equipment through the spa control panel or wireless remote is permitted and acceptable Do not connect any auxiliary components for example cable additional speakers headphones additi...

Page 5: ...e recommended levels for your CALDERA spa are Free Available Chlorine 3 0 5 0 ppm Total Alkalinity 40 120 ppm Water pH 7 2 7 8 Calcium Hardness 50 150 ppm Refer to Water Quality and Maintenance sectio...

Page 6: ...can easily be diagnosed over the telephone by an Authorized Service Technician SPA SHELL Your CALDERA spa has an acrylic shell Stains and dirt generally will not adhere to your spa s surface Asoft ra...

Page 7: ...aptaFlo jet allow you to redirect the jet stream by changing the position of the nozzle 9 The Euro Directional jets with eyeball nozzles deliver a direct more focused massage 10 The Euro Pulse jets fe...

Page 8: ...unter clockwise to reduce the force or clockwise to increase the force Notice that turning off the flow to some jets increases the flow to the other jets To avoid damage to your spa s plumbing and com...

Page 9: ...pH Alkalinity Up Down available Know the Hardness of your water contact your dealer to help you with this information See Water Quality and Maintenance for more information IMPORTANT WATKINS WELLNESS...

Page 10: ...0 ppm then spa water pH to between 7 2 and 7 8 These procedures are listed in the Water Quality and Maintenance section OPERATION NOTE Adjusting the Total Alkalinity as the first step is important as...

Page 11: ...a responsible person to handle spa chemicals Keep them out of the reach of children Accurately measure the exact quantities specified never more Do not overdose your spa Handle all containers with car...

Page 12: ...ween 7 2 7 8 To lower the pH level use MONARCH pH Alkalinity Down sodium bisulfate To raise the pH level use pH Alkalinity Up sodium carbonate Water Conditioners Spa fill water varies from location to...

Page 13: ...spa by adding MONARCH MPS Plus non chlorine shock shock or sodium dichlor chlorine To replace FROG cartridges follow these steps 1 Turn off power to the spa 2 Unscrew FROG cap on top edge of spa 3 Tur...

Page 14: ...hlorine chloramines has a strong chlorine odor that can be eliminated by shocking the water IMPORTANT There are several forms of stabilized chlorine available for use in spas and swimming pools It is...

Page 15: ...popular water additives that are optional Mineral Deposit Inhibitors As water evaporates from your spa and new water is added the amount of dissolved minerals will increase Minimize evaporation by ke...

Page 16: ...f nitric acid a highly corrosive chemical is a byproduct of the ozone generating process Nitric acid is produced in very small quantities and is readily dissolved in the water stream with ozone Oxidiz...

Page 17: ...ycle is on 38 0c Settings Screen Press this icon to access the first Settings screen Home Screen Features 38 0c Jets Press this icon to access the Jets Control screen 38 0c Music If installed press th...

Page 18: ...Summer Timer On or Off TEMPERATURE LOCK Press 38 0c on Home screen to display Temperature Lock The Temperature Lock feature prevents changing the desired water temperature setting All other control p...

Page 19: ...SPA LOCK OFF ON LIGHTS TIMER OFF ON SUMMER TIMER OFF ON to see more languages Press and hold on the new desired language until it turns green Press to start the conversion process The conversion is f...

Page 20: ...S section and the ALL LIGHTS section MOODS Preset colors and brightness LIGHTS 1 2 3 4 MOODS ALL LIGHTS Press to turn On Underwater lights blue color LIGHTS 1 2 3 4 MOODS ALL LIGHTS Press to turn On U...

Page 21: ...rnal lights on full intensity 5th press Underwater lights and EUPHORIA Jets lights on low intensity external lights on full intensity 6th press Underwater lights and EUPHORIA Jets lights off external...

Page 22: ...k Jet Leg Jets Neck and Upper Back Jets Lower Back and Feet Jets Leg Jets Neck and Upper Back Jets Lower Back and Feet Jets Lower Back and Feet Jets Step 6 Lower Back and Feet Jets Leg Jets Leg Jets L...

Page 23: ...URO PULSE jets d 4 Euro Directional jets e 1 ACQUARELLA Waterfall a b b c c d d e JET PUMP 2 JET SYSTEM 1 a 8 Euro Directional jets b 2 VERSASSAGE jets c 2 EURO PULSE jets d 1 ACQUARELLA Waterfall a a...

Page 24: ...1 EUPHORIA jet f ACQUARELLA Waterfall JET PUMP 2 JET SYSTEM 1 Located in ULTRAMASSAGE lounge a 2 VERSASSAGE jets b 2 ORBISSAGE jets c 6 Euro Directional jets d 6 Sole Soothers jet e ACQUARELLA Waterf...

Page 25: ...MP 1 JET SYSTEM 1 a 2 VERSASSAGE jets b 4 Euro Directional jets c 1 EUPHORIA jet JET PUMP 2 JET SYSTEM 2 Located in ECSTASEAT a 2 Directional Neck jets b 2 Euro Directional jets Located in ULTRAMASSAG...

Page 26: ...SSAGE jets d 2 ORBISSAGE jets e ACQUARELLA Waterfall JET PUMP 1 JET SYSTEM 2 a 2 Euro Directional jets b 1 ADAPTAFLO jet Located in LUMBARSSAGEseat c 2 VERSASSAGE jets d 6 Euro Directional jets e 1 AD...

Page 27: ...P 1 JET SYSTEM 1 Located in LUMBARSSAGEseat a 2 Euro Directional jets b 2 ORBISSAGE jets c 2 VERSASSAGE jets d 2 Euro Directional jets e 2 ADAPTASSAGE jets JET PUMP 2 JET SYSTEM 1 Located in ECSTASEAT...

Page 28: ...SAGE lounge a 2 Directional Neck jets b 12 Euro Directional jets c 2 ORBISSAGE jets d 2 VERSASSAGE jets JET PUMP 2 JET SYSTEM 1 Located in ECSTASEAT lounge a 22 Euro Directional jets b ACQUARELLA Wate...

Page 29: ...filter cartridge To return basket and floating weir insert and rotate clockwise to lock into position Then turn spa s power back on NOTE Replacement filter cartridges are available from your CALDERA d...

Page 30: ...correctly can lead to freeze damage not covered by warranty It is strongly recommended that you contact your local dealer to perform this service 1 Drain your spa following the Draining Your Spa secti...

Page 31: ...ohol or any other household cleaner other than those listed to clean the spa shell surface is NOT recommended DO NOT use any cleaning products containing abrasives or solvents since they may damage th...

Page 32: ...ditional 16 amp breaker the heater will NOT operate while the jets in the lounge jet pump 3 are on Mount the subpanel according to local codes but not closer than 1 5 meters 5 feet away Your spa must...

Page 33: ...maximum safety against electric shock Remember connecting the spa to an improperly wired circuit will negate many of its safety features NOTE Long wiring runs may require larger gauge wire than state...

Page 34: ...ting Your CALDERA dealer can help you with local information such as zoning regulations and building codes They can also give you a copy of our planning guide CAUTION Do not install the spa on a heate...

Page 35: ...nforced concrete pad at least 10 cm 4 inches thick or a deck that is able to withstand more than 515 kg m is recommended for the PROVENCE 610 kg m is recommended for TAHITIAN spa and 600 kg m is recom...

Page 36: ...ons are approximate measure your spa before making critical design or pathway decisions 108 0 274 cm 32 5 83 cm 38 97 cm 102 0 259 cm 85 125 216 cm Cantabria 93 375 237 cm 13 33 cm 61 5 156 cm 91 231...

Page 37: ...o support the dead weight found in the spa specification chart WARNING The GENEVA NIAGARA must not be shimmed in any manner Niagara Geneva 89 226 cm 32 5 83 cm 38 97 cm 83 5 212 cm 83 5 212 cm 75 190...

Page 38: ...imensions are approximate measure your spa before making critical design or pathway decisions 84 0 213 cm 31 79 cm 36 91 cm 78 25 199 cm 78 25 199 cm TAHITIAN 69 5 177 cm 37 875 96 cm 13 33 cm 84 213...

Page 39: ...e to support the dead weight found in the spa specification chart WARNING The PROVENCE must not be shimmed in any manner 84 0 213 cm 31 79 cm 35 89 cm 78 5 199 cm 71 85 182 5 cm PROVENCE 69 5 177 cm 3...

Page 40: ...to note that the heater is protected by both the heater high limit thermostat circuit and the integrated pressure switch The causes of heater high limit tripping are discussed in the previous section...

Page 41: ...n equal to the duration of the applicable limited warranty stated above Some states do not allow limitations on how long an implied warranty lasts Under no circumstances shall WATKINS WELLNESS or any...

Page 42: ...Gray Logo Power indicator blinking Heater high limit thermostat tripped Disconnect power for at least thirty seconds to reset heater high limit If it will not reset check for clogged filters If tripp...

Page 43: ...or panel away from the spa next to that button location Repeat procedure on second button Main Control Panel Safety Lock DOOR PANEL REPLACEMENT 1 Raise door panel placing top under Stainless border wi...

Page 44: ...circuit NIAGARA 226 cm x 226 cm 97 cm 10 m 3 000 1 525 liters 450 kg 2 535 kg 600 kg m 230 volt 16 and 25 amp Single phase GFCI protected circuit TAHITIAN 213 cm x 213 cm 91 cm 10 m 3 000 1 425 liter...

Reviews: