SR
-SERIES
61
Example B
200,000 Btu/hr input - 80' (24.4m) reflector package, with
10’
(3m) of outside air intake duct and 1 - 90°
elbow in the exhaust vent.
Calculation:
Total maximum length of heater c/w outside air & exhaust vent is:
110' (33.6m)
Total combined length of heater and exhaust in this example is:
Heater Length:
80' (24.4m)
Exhaust length:
10' (3m)
90° Exhaust vent elbow:
10' (3m)
TOTAL COMBINED LENGTH:
100' (30.5m)
Amount to be deducted from total available length:
-100' (30.5m)
Conclusion:
The Maximum length of fresh air duct in this example is:
10* (3m)
If condensation in exhaust venting is present then venting should be insulated or shortened. In Canada, install
according to the
Natural Gas and Propane Installation Code, CSA B149.1
or latest edition and in the USA, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54
or latest edition.
NOTE: For venting of two or more heaters into one common chimney, in Canada refer to the
Natural Gas and
Propane Installation Code, CSA B149.1
or latest edition and in the USA, the
National Fuel Gas Code,
ANSIZ223.1/NFPA 54
or latest edition.
NOTE: A small amount of condensation may occur from the heater when it starts the heating cycle. The
condensation should stop once the heater warms up. Make sure venting is sealed as previously noted. The
amount of condensation will increase the lower the ambient temperature is in the environment the heater is
operated
Summary of Contents for SR Series
Page 18: ...SR SERIES 14 PIPE BOXES Figure 11 PIPE BOX CONTENT...
Page 19: ...SR SERIES 15 10 3 M REFLECTOR PACKAGE Figure 12 10 3 M REFLECTOR PACKAGE CONTENTS...
Page 20: ...SR SERIES 16 15 4 16 M REFLECTOR PACKAGE Figure 13 15 4 16 M REFLECTOR PACKAGE CONTENTS...
Page 21: ...SR SERIES 17 20 6 1 M REFLECTOR PACKAGE Figure 14 20 6 1 M REFLECTOR PACKAGE CONTENTS...
Page 22: ...SR SERIES 18 30 9 1 M REFLECTOR PACKAGE Figure 15 30 9 1 M REFLECTOR PACKAGE CONTENTS...
Page 23: ...SR SERIES 19 40 12 2 M REFLECTOR PACKAGE Figure 16 40 12 2 M REFLECTOR PACKAGE CONTENTS...
Page 24: ...SR SERIES 20 50 15 2 M REFLECTOR PACKAGE Figure 17 50 15 2 M REFLECTOR PACKAGE CONTENTS...
Page 25: ...SR SERIES 21 60 18 3 M REFLECTOR PACKAGE Figure 18 60 18 3 M REFLECTOR PACKAGE CONTENTS...
Page 26: ...SR SERIES 22 70 21 3 M REFLECTOR PACKAGE Figure 19 70 21 3 M REFLECTOR PACKAGE CONTENTS...
Page 27: ...SR SERIES 23 80 24 4 M REFLECTOR PACKAGE Figure 20 80 24 4 M REFLECTOR PACKAGE CONTENTS...
Page 28: ...SR SERIES 24 10 3 M EXTENSION KIT Figure 21 10 3 M EXTENSION PACKAGE CONTENTS...
Page 29: ...SR SERIES 25 SIDE REFLECTOR PACKAGE Figure 22 SIDE REFLECTOR PACKAGE CONTENTS...
Page 56: ...SR SERIES 52 SIDE REFLECTOR Figure 52 SIDE REFLECTOR INSTALLATION...
Page 78: ...SR SERIES 74 24 0 GAS VALVES Figure 62 GAS VALVE Figure 63 PRESSURE REGULATOR...
Page 94: ...SR SERIES 90...
Page 95: ...SR SERIES 91...