8/18/2021
LMU-2600 Hardware & Installation Guide - PULS Wiki
https://puls.calamp.com/wiki/LMU-2600_Hardware_%26_Installation_Guide
5/44
LMU Manager is the primary configuration tool in the CalAmp system. It allows access to almost every
feature available to the LMU-2600™. Unlike the backend software, it has the option of talking directly to an
LMU-2600™ or making a request forwarded by the LM Direct™ server.
For further details on using LMU Manager, please refer to the LMU Manager Users Guide.
3 Hardware Overview
3.1 Location Messaging Unit-LMU-2600™
3.1.1 LMU-2600™ Handling Precautions
Electrostatic Discharge (ESD)
Electrostatic discharge (ESD) is the sudden and momentary electric current that flows between two objects at
different electrical potentials caused by direct contact or induced by an electrostatic field. The term is usually
used in the electronics and other industries to describe momentary unwanted currents that may cause damage
to electronic equipment.
ESD Handling Precautions
ESD prevention is based on establishing an Electrostatic Protective Area (EPA). The EPA can be a small
working station or a large manufacturing area. The main principle of an EPA is that there are no highly
charging materials in the vicinity of ESD sensitive electronics, all conductive materials are grounded, workers
are grounded, and charge build-up on ESD sensitive electronics is prevented. International standards are used
to define typical EPA and can be obtained for example from International Electro-technical Commission (IEC)
or American National Standards Institute (ANSI).
This ESD classification of the sub assembly will be defined for the most sensitive component, therefore the
following classifications apply:
Class 1B – Human Model (< 1 kV)
Class M1 – Machine Model (< 100V)
When handling the LMU-2600’s™ main-board (i.e. sub assembly) by itself or in a partial housing proper ESD
precautions should be taken. The handler should be in an ESD safe area and be properly grounded.
WARNING:
This product can expose you to chemicals including carbon black, nickel, & bisphenol A,
which are known to the State of California to cause cancer and birth defects or other reproductive harm. For
more information go to
https://www.P65Warnings.ca.gov
GPS Ceramic Patch Handling
When handling the sub assembly it may be natural to pick it up by sides and make contact with the antenna
boards. In an uncontrolled ESD environment contact with the center pin of ceramic patch antenna can create a
path for electrostatic discharge directly to the GPS Module. The GPS Module is very sensitive to ESD and can
be damaged and rendered non-functional at low levels of ESD.
One should avoid contact with the center pin of the patch during handling.