background image

2010 Portable Spa

LTR20101000, Rev. C

Using the Enter

tainment System

www.calspas.com

41

Using the iSound Remote Music System

The iSound Remote Music System comes with the SoundCast iCast transmitter 

and OutCast wireless speaker. This is a stand-alone audio product manufactured 

by SoundCast Systems. It is not integrated with any Cal Spa product.
The OutCast system is ideal for use outdoors and especially in an environment 

with a pool or spa. The portable wireless speaker is extremely water resistant 

(but not waterproof) and is free from interference from other wireless devices 

such as cordless or cell phones, microwave ovens, remotes, or wireless routers.
The  OutCast  system  comes  with  its  own  owner’s  manual.  It  describes  parts 

included, installation, and proper use. Owners of the OutCast system must read 

this manual.
The iCast Transmitter is tailored to the needs of Apple 

iPod owner. The iCast transmitter is specially configured 

to  accommodate  currently  available  iPods,  using 

approved interchangeable inserts in the docking bay.
Note:  The  OutCast  system  includes  an  MP3 

docking station, transmitter, and remote speaker 

and does NOT INCLUDE an MP3 player such as 

an iPod .

About the SunBriteTV Monitor

Because Cal Spas does not offer an integrated TV or DVD 

option with any line of spas, we recommend spa owners 

use the SunBriteTV monitor as a high quality, weather 

resistant video monitor.
The SunBriteTV monitor is a stand-alone video product 

and  is  not  manufactured  by  Cal  Spas.  The  SunBriteTV 

monitor comes with its own owner’s manual. Owners of 

the SunBriteTV must read this manual.
It is designed for permanent outdoor installation and is 

suitable for use adjacent to your spa.
This  television  is  highly  adaptable  to  most  kinds  of 

installation with a wide variety of video input options such 

as DVD or cable TV and easily customizable according to 

spa owners’ preferences and circumstances.
You will need to coordinate the installation of your video system with your spa dealer.

THE SUNBRITETV MUST BE INSTALLED NO LESS THAN FIVE FEET AWAY FROM ANY BODY OF WATER 

(SUCH A POOL OR SPA).
Check local building codes and consult your spa dealer for proper installation guidelines.

Summary of Contents for LTR20101000

Page 1: ...LTR20101000 Rev C 2 28 10...

Page 2: ...Perimeter Lighting 23 Clear Water Plan The Key to Clear Water 24 Testing and Adjusting Spa Water 25 Sanitation 26 About the Pure XL Water Sanitizer 28 Filter Cleaning 28 CONTACT INFORMATION For custom...

Page 3: ...r water can induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level 3 F to 6 F above the normal body temperature of 98 6 F or 2 C to 4 C above 37 C While hype...

Page 4: ...es should not use a spa or hot tub WARNING To avoid injury exercise care when entering or exiting the spa or hot tub WARNING Do not use drugs or alcohol before or during the use of a spa or hot tub to...

Page 5: ...will you use your spa for recreational or therapeutic purposes If your spa is mainly used for family recreation be sure to leave plenty of room around it for activity If you will use it for relaxatio...

Page 6: ...l void your warranty and may result in serious injury When installed in the United States the electrical wiring of this spa must meet the requirements of National Electric Code ANSI NFPA 70 2008 and a...

Page 7: ...high power setting See configuration instructions on page 6 One 60 amp GFCI Four 8 AWG copper wires Ultimate Fitness Spas Fitness spa with 5 5 kW heater F854 F1257 FP2400 One 50 amp GFCI Four 8 AWG c...

Page 8: ...igher power than other 240V systems Dip switch 10 is factory set in the ON position This causes the heater to shut off when any pump is running in high speed To allow the heater to continue operating...

Page 9: ...2010 Portable Spa LTR20101000 Rev C Preparing for Your New Portable Spa www calspas com 7 GFCI Wiring Diagram...

Page 10: ...our warranty All Ultimate Fitness Series spas are plumbed with a gas heater ready union located inside the cabinet at either the front or rear depending on the model See the figures below and at right...

Page 11: ...2010 Portable Spa LTR20101000 Rev C Preparing for Your New Portable Spa www calspas com 9...

Page 12: ...ature reaches the default temperature of 100 F If no water is flowing when the pump is running 8 there could be an air pocket at the suction side of the pump Shut off power to the spa and loosen the p...

Page 13: ...n Standard Mode The second method will remove a large air lock within the pump Using a Phillips screwdriver remove the front 1 panel from the spa and locate the pump While the spa is operating turn th...

Page 14: ...pump should be left in the off position for 10 to 15 seconds Repeat steps 1 through 3 until water is flowing 4 through all the jets and all air is removed from the plumbing When the spa has finished p...

Page 15: ...ontrol Pump 2 and Pump 3 Sequence Press Option button once to activate high speed pump 2 Press Option button twice to activate high speed pump 3 and high speed pump 2 Press three times to activate pum...

Page 16: ...l heat to 100 F 37 5 C at start up until the set temperature is changed as described below Temperature Adjustment Range 80 F to 104 F 26 C to 40 C The start up temperature is set at 100 F 37 5 C The l...

Page 17: ...once to turn pump 2 on or off and to shift between low and high speeds if it is a two speed pump If left running the pump will turn off after 15 minutes Option This is an optional feature Press the OP...

Page 18: ...nerator will run for one hour Ozone This is an optional feature On most systems the ozone generator if installed runs during filter cycles except when pump 1 is operating at high speed on a non circ u...

Page 19: ...em Operation The Sounds Good system is available on 9800 controls only When you press the button once it activates the sound system You will hear a unique sound for each button you press on the contro...

Page 20: ...control panel will be disabled until power returns Spa settings and time of day will be preserved for 30 days with a battery back up BUF Internal problem detected Repair required Contact your dealer o...

Page 21: ...n turn power back on If display message is repeated then shut the power off to the spa and call your dealer or service organization Pr When your spa is first actuated it will go into priming mode The...

Page 22: ...before use set the temperature to the desired temperature If the spa usage exceeds two hours a week the set temperature should remain at the desired usage temperature The air venturis should be used...

Page 23: ...ases from floor jets to wall jets This is ac complished by rotating the diverter knob to the left counterclockwise decreasing the amount of wa ter flow through a section of jets To increase the amount...

Page 24: ...This button allows the user to cycle down through all seven massage modes one at a time Time Reset Mode Pulse mode will normally run for 15 minutes then automatically shut off For another 15 minute se...

Page 25: ...r White Cyan Magenta Blue Yellow green Green Red To cycle through the different color choices press the button repeatedly Each time you press the button you advance to the next color Flashing white 2...

Page 26: ...ip exeraestie estie vel inisci elisl ut diat cons aut alit lut lore tin hent adiam iustrud molor sustis essit wis cilit wisi Chemical Balance Ing et augait alit esto dolut dio dole niam quat am vel et...

Page 27: ...alkalinity is 80 120 ppm If the TA is too low the pH level will fluctuate widely from high to low Low TA can be corrected by adding Cal Spas pH Alkalinity Up If the TA is too high the pH level will te...

Page 28: ...ther organic waste by breaking them down to non harmful levels and are filtered out Make sure you follow all instructions and use only Cal Spas brand chemicals Whichever plan you decide on follow it c...

Page 29: ...a week After heavy bather loads If water has a strong odor Spa must be running with all of the jets on high for 30 minutes with the cover open If necessary repeat oxidizer shock in 30 minute intervals...

Page 30: ...to the bucket of water Note It is a good idea to keep a spare filter to use in the spa while the dirty filter is being deep cleaned This way you can rotate the filters and both will last longer Twist...

Page 31: ...or spa s components from improper chemicals or chemical usage is not covered under the spa s warranty Prior to filling a spa for the first time or after a routine draining you will want to follow this...

Page 32: ...surface with Fast Sheen Clean and treat spa cover pillows and Cal Select cabinet if equipped with Cover Protector Refill your spa following the section Starting the Spa with Fresh Water If you are us...

Page 33: ...ount of chlorine as a supplemental 1 sanitizer Based on the test strip readings 2 Adjust total alkalinity acceptable range of 80 120 ppm Adjust the pH if needed range is between 7 2 to 7 8 Add 1 table...

Page 34: ...e and 12 adjust sodium bromide level to 7 4 to 8 2 equates to 1700 to 2500 ppm TDS level Add 2 oz of Cal Spas Oxidizer Shock to help burn 13 out impurities in fill water Turn the dial on the bromine g...

Page 35: ...efill the spa Organic buildup scum ring around spa Buildup of oils and dirt Wipe off scum with clean rag if severe drain the spa use a spa surface and tile cleaner to remove the scum and refill the sp...

Page 36: ...ntenance Spa Cover Important Keep the spa covered when not in use Covered spas will use less electricity in maintaining your set temperature Covering your spa will protect your spa s finish from the s...

Page 37: ...cate hose ending with the 3 4 inch hose bib 4 fixture Hook up the female end of a garden hose to the drain fitting 5 Place the other end of the garden hose where you would like the water to drain to 6...

Page 38: ...e pumps 5 Disconnect the unions from both sides of the pump 6 Blow any remaining water out of the jets and equipment 7 area with the wet dry vacuum Cover your spa with a good spa cover and an all weat...

Page 39: ...ll with our Cal Spas All Purpose Cleaner and apply a protective coat of Cal Spas Fast Sheen Cal Spas All Purpose Cleaner is a low detergent non abrasive cleaner specifically formulated to clean the sp...

Page 40: ...eel some resistance Continue to rotate the jet for another quarter turn You will feel the jet snap out of position Continue to rotate the jet as you pull it out of the jet well To replace jets insert...

Page 41: ...ake every precaution to keep this system dry Water damage is not covered by Cal Spas or the manufacturer s warranty Using the Entertainment System Listening to the Radio Press the POWER button on the...

Page 42: ...on the remote for the device you want to program TV CD DVD etc 2 Press and hold the SETUP button until the LED blinks twice 3 Enter the device code If you perform this procedure correctly the LED wil...

Page 43: ...d interchangeable inserts in the docking bay Note The OutCast system includes an MP3 docking station transmitter and remote speaker and does NOT INCLUDE an MP3 player such as an iPod About the SunBrit...

Page 44: ...MFW 4 Maxi Flow Stainless steel PLU21703630 Cobalt blue PLU21703630 BLU mfw 3 Micro Flow Stainless steel PLU21703631 Cobalt blue PLU21703631 BLU Jets MJW 5 5 Shower Storm Stainless steel PLU21703625...

Page 45: ...PLU21703609 BLU Jet Stream Propulsion PLU21702620 Valves 1 LED Diverter Valve with Swoosh Logo PLU21300450 2 LED Diverter Valve with Swoosh Logo PLU21300460 1 Diverter Valve Silver Handle with Dark Gr...

Page 46: ...in Star Suction Cover PLU21400197 Bottom Drain Filtration Return Assembly OZO18300005 Waterfalls Cascade Waterfall PLU21800820 Filter Waterfall PLU21800830 Vertical Waterfall PLU21800840 Filters Filte...

Page 47: ...ion of replacement cabinets for all models is very extensive and too lengthy for this owner s manual See your Cal Spas deal to order replacement panels for your spa or call 1 800 CAL SPAS Lights Light...

Page 48: ...2 Standard Palomino ACC01200454 Deluxe Rust ACU02200290 Deluxe Gray ACU02200291 Deluxe Slate ACU02200295 Deluxe Palomino ACU02200289 Diamond Series D836L D836B D847M D850L D850B D865B D865L 93 X 93 St...

Page 49: ...CU02200250 Deluxe Gray ACU02200251 Deluxe Slate ACU02200256 Deluxe Palomino ACU02200257 Custom Teal ACU02200252 Custom Navy ACU02200253 Custom Hunter ACU02200254 D635V 84 X 93 Standard Rust ACC0120046...

Page 50: ...o ACU02200217 Deluxe Teal ACU02200212 Deluxe Navy ACU02200213 Deluxe Hunter ACU02200214 FII730 FII745 84 x 84 Standard Rust ACC01200410 Standard Gray ACC01200411 Standard Slate ACC01200412 Standard Pa...

Page 51: ...rd Rust ACC01200520 Standard Gray ACC01200521 Standard Slate ACC01200522 Standard Palomino ACC01200523 VX726B L VX740L 84 x 84 Standard Rust ACC01200410 Standard Gray ACC01200411 Standard Slate ACC012...

Page 52: ...body with your elbows slightly bent Pull your body forward bringing hands together squeezing and flexing chest muscles then slowly returning to the starting position Standing Chest Press Using the ex...

Page 53: ...ortable Spa LTR20101000 Rev C Appendix www calspas com 51 Connecting the Exercise Equipment The drawings below show different ways the exercise kit can be connected depending on the exercises you wish...

Page 54: ...the spa Contact your dealer Heat Problems Spa does not heat Heating mode not selected See control panel instructions on pages 12 through 16 Water level is too low Add water to correct level No electri...

Page 55: ...and empty the hoses Close or turn off empty cycle if necessary Water Pressure Problems Jets surge on and off Water level is too low Add water to normal level Jets are weaker than normal or do not wor...

Page 56: ...ontact your dealer Pump turns off during operation Automatic timer has completed its cycle Start the cycle again Pump has overheated due to the vents on the equipment door being blocked Clear items aw...

Page 57: ...2010 Portable Spa LTR20101000 Rev C Appendix www calspas com 55 Cal Spas Chemicals...

Page 58: ...delamination of Altair Plus Quarite Plus interior surfaces 2 Years 3 Years 3 Years 5 Years Interior Surface Standard Acrylic Quarite LMS warrants against cracks blisters peeling discoloration and dela...

Page 59: ...the normal operating range of 32 F 0 C to 118 F 47 8 C Damage caused by incorrect water level low overflow etc Damage caused by extreme weather conditions hot cold etc Damage caused by dirt sand and c...

Page 60: ...________________________ Date Installed _________________________________________________________________________ Dealer s Phone Number ________________________________________________________________...

Reviews: