All 230V spas must be permanently connected
(hardwired) to the power supply. These instructions
describe the only acceptable electrical wiring
procedure. Spas wired in any other way will void your
warranty and may result in serious injury.
This is the only acceptable electrical wiring procedure.
Spas wired in any other way will void your warranty.
See the wiring diagram on page 8.
The electrical wiring of this spa must meet the
requirements of any applicable local, state, and federal
codes. The electrical circuit must be installed by an
electrical contractor and approved by a local building /
electrical inspector.
RCD and Wiring Requirements
The power supplied to the spa must be on a dedicated
RCD protected circuit with no other appliances or
lights sharing the power.
Use copper wire with THHN insulation. Do not use
aluminum wire.
Use the table below to determine your GFCI and wiring
requirements.
When wires larger than #6 AWG are required, install
a junction box near the spa and use #6 AWG wire
between the junction box and the spa.
Wire runs over 26 m must increase wire gauge to the
next lower number. For example: A normal 50 amp
RCD with four #8 AWG copper wires run over 26
m would require you to go to four #6 AWG copper
wires.
Testing the RCD Breaker
Test the RCD breaker prior to first use and periodically
when the spa is powered. To test the RCD breaker
follow these instructions (spa should be operating):
Press the TEST button on the RCD. The RCD will
1.
trip and the spa will shut off.
Reset the RCD breaker by switching the breaker
2.
to the full OFF position, wait a moment, then turn
the breaker back on. The spa should have power
again.
230 Volt Electrical Installation
All portable spas (except Fitness Spas)
Spa Model
Control
Box
Services
GFCI Required
Wires Required
All portable spas
(except Fitness Spas)
6115 and
6215
Single
One 32 amp RCD or one
16 amp RCD
Three #10 AWG copper
wires
Dual
Two 16 amp RCDs
Five #10 AWG copper
wires
8015
Single
One 32 amp RCD or one
16 amp RCD
Three #10 AWG copper
wires
Dual
Two 16 amp RCDs
Five #10 AWG copper
wires
Summary of Contents for F 1239
Page 2: ...LTR20121001 Rev A 12 30 11...
Page 51: ...2012 Portable Spa LTR20121001 Rev A Appendix www calspas com 48...
Page 52: ...2012 Portable Spa LTR20121001 Rev A Appendix www calspas com 49...
Page 54: ...LTR20121001 Rev A 12 30 11...
Page 104: ...2012 Spas portables LTR20121001 Rev A Appendix www calspas com 49...
Page 106: ...LTR20121001 Rev A 12 30 11...
Page 156: ...2012 Verplaatsbare bubbelbaden LTR20121001 Rev A Aanhangsel www calspas com 49...
Page 158: ...LTR20121001 Rev A 12 30 11...
Page 208: ...2012 spa portat l LTR20121001 Rev A Ap ndice www calspas com 49...
Page 210: ...LTR20121001 Rev A 12 30 11...
Page 260: ...2012 Transportierbaren Wellnessb der LTR20121001 Rev A Anhang www calspas com 49...
Page 262: ...LTR20121001 Rev A 12 30 11...
Page 312: ...2012 Flyttbare uttend rs boblebad LTR20121001 Rev A Tillegg www calspas com 49...