Appendix
23
Hibachi Grill
LTR50001096, Rev. A
www.calflamebbq.com
Problem: Plugged orifice
Solution:
Unplug the orifice as follows:
Remove griddle and grease tray.
•
Remove burners from the bottom of the firebox by
•
pulling the cotter pin from beneath the burner peg
using a standard screwdriver or needle nose pliers.
Carefully lift each burner up and away from the gas
•
orifice.
Remove the orifice from the control valve.
•
Gently clear any obstruction with a fine wire.
•
Reinstall the orifice, reinstall the burners over the
•
orifices, and seat each burner peg into position hole
at the bottom ledge of the firebox.
Replace all cotter pins.
•
Replace cooking components and grease collectors.
•
If an obstruction is suspected in the control valve, con-
tact your local Cal Flame dealer for assistance.
Problem: Burner tube is misaligned over the orifice
Solution:
Reposition the burner tube so that it is properly seated
over the orifice.
Problem: Obstruction in the gas line
Solution:
Remove the fuel line from grill. (Do not smoke or per-
form any maintenance in the vicinity of an open flame.)
Open the gas valve for one second to blow out any de-
bris. Close off the gas valve and reconnect the fuel line
securely.
Summary of Contents for BBQ10900
Page 1: ......