ENCORE VENTI Rev. 3 2021-10
www.cafection.com 800-561-6162
66
SERVICE & INSTALLATION MANUAL for Cafection's Encore Venti
7.8.3 Soluble Canisters
Soluble Whipper Assembly
Frequency: weekly or every 200 cycles
If there is product accumulation, remove the soluble whipper
assembly for manual cleaning under hot water.
1. Remove the tube from the base.
2. Lift the funnel. Remove the whipper chamber and the
propeller or disk (milk), then twist off the whipper base.
3. Clean all parts and gaskets with hot water. Use the small
brush for tubes if necessary.
4. Air dry completely.
5. Reinstall all parts in reverse order.
6. Order a large beverage of each soluble to ensure that all
parts and switches are working properly.
Soluble Canisters
Frequency: monthly or every 1,000 cycles
It is recommended to remove, empty and clean the
soluble canisters every month to avoid powder to
accumulate on the walls of the canisters and alter the
quality of the beverages.
1. Open the brewer’s door.
2. Pull the canisters out of the brewer to disengage
them from the motor and transmission. Tilt the
canisters carefully to disengage them from the top
walls while avoiding powder fall.
3. Clean and sanitize under hot water and air dry
completely.
4. Reinstall all parts and reload products in the
canisters.
5. Order a large beverage of each soluble to confirm
that all parts and switches are working properly.
7.8.4 Coffee Whipper
Coffee Whipper Assembly
Frequency: weekly or every 200 cycles
1. Remove the base of the whipper.
2. Rinse under hot water.
3. Air dry completely.
4. Reinstall all the parts in the reverse order.
5. Order a large beverage to confirm that all the
parts are in place.
C