ENCORE VENTI Rev. 3 2021-10
37
www.cafection.com 800-561-6162
SERVICE & INSTALLATION MANUAL for Cafection's Encore Venti
6.3
Status Tab
To access the screen below, press the SW2 button (white) on the main board inside the brewer’s door
(see section 3.6) and select the Status tab.
1. Service Notes. Allows the technician to enter the servicing that has been performed on the machine.
An alphanumeric keyboard will appear when clicking the text box.
2. Unit model.
3. Software version of the computer.
4. Serial number of the coffee brewer. Correct serial number is necessary for
Sophia
. Service users
with level 4 access can set the serial number (see section 6.1).
5. Firmware version of the microcontroller (EPROM).
6. Firmware version of the thermostat’s microcontroller.
7. Actual water temperature in Fahrenheit.
8. Time and date. Date and time can be set in the Tools sub tab, under the System tab.
9. Cup Sensor status.
10. Network status. Many possible statuses:
Disabled: Network is offline.
Invalid serial num.: Serial number shown on screen is invalid. Verify the serial number (see
section 6.6.4).
Wi-Fi no link: Wi-Fi link is activated but the network is not functioning.
Wi-Fi link OK: Wi-Fi link is activated and coffee brewer is connected to the network.
Cell. Modem no link: Cellular modem link is activated but the network is not functioning.
Cell. Modem link OK: Cellular modem link is activated and coffee machine is connected to the network.
Ethernet no link: Ethernet link is activated but the network is not functioning.
Ethernet link OK: Ethernet link is activated and coffee machine is connected to the network.
11. Activation key of the brewer. It is used to register the machine on
Sophia
.
12. Error log keeping the last 50 events in memory, accessible remotely on
Sophia
(Optimum License
required).
S
e
rv
ic
e Mo
d
e
1
2
3
5
4
9
6
7
8
12
11
10
Encore Venti
XXXX-XXXXXXX