16 CHANNEL 

I/O Register (Status A) 

MANUAL REV.1

 

NPO: 
00118/01:V977X.MUTX/01 

Summary of Contents for V977

Page 1: ...Technical Information Manual MOD V977 27 August 2004 Revision n 1 16 CHANNEL I O Register Status A MANUAL REV 1 NPO 00118 01 V977X MUTX 01...

Page 2: ...he User accident or any abnormal conditions or operations CAEN declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of the User It i...

Page 3: ...TECHNICAL SPECIFICATION TABLES 7 2 6 FRONT PANEL 8 3 OPERATING MODES 9 3 1 FUNCTIONAL DESCRIPTION 9 3 1 1 I O register mode 10 3 1 2 Multihit pattern unit mode 10 3 1 3 Test channel 11 3 2 OR LOGIC 1...

Page 4: ...ERRUPT VECTOR 19 4 17 SERIAL NUMBER 19 4 18 FIRMWARE REVISION 19 4 19 CONTROL REGISTER 19 4 20 DUMMY16 20 4 21 SOFTWARE RESET 20 REFERENCES 21 LIST OF FIGURES FIG 2 1 MOD V977 FRONT PANEL 8 FIG 3 1 MO...

Page 5: ...t panel pushbutton The TEST output signal can be either NIM or TTL selected with the same on board switch of the channels output Input signals can be individually masked via VME or globally via a fron...

Page 6: ...IM or TTL LEMO 00 50 impedance 2 OR and NOT OR OUTPUT NIM or TTL selectable LEMO 00 LEDS Name Function Color 16 I O STATUS Depends on the module s programming status see 3 1 Green 16 I O STATUS Depend...

Page 7: ...ess selection No 1 jumper for the output signal type selection up NIM down TTL 2 4 Power requirements Table 2 1 Power requirements Power supply Current absorption 5 V 2 3A 2 5 Technical specification...

Page 8: ...27 08 2004 1 NPO Filename Number of pages Page 00118 01 V977X MUTX 01 V977_REV1 DOC 21 8 2 6 Front Panel Fig 2 1 Mod V977 Front Panel Mod V977 16 CH STATUS A I O REGISTER PATTERN UNIT CLR DTACK TST O...

Page 9: ...ons The two cascaded FLIP FLOPs as shown in Fig 3 1 allow to detect the following events none one or two input hits The FLIP FLOPs status of all channels can be read via VME in the SINGLEHIT READ REGI...

Page 10: ...READ VME REGISTER OUTPUT MASK VME REGISTER OUTPUT SET VMEREGISTER CLEAR OUTPUT VME REGISTER INPUT CLEAR AR Fig 3 2 I O register mode In this operating mode the output of one channel is active when a s...

Page 11: ...3 Multihit pattern unit mode In this operating mode the output of one channel is active when a double hit from front panel or VME generated is present The output can also be set by a write access to...

Page 12: ...as front panel signals and can be eventually masked Also the TEST signal participates to the OR logic it can also be masked 3 3 Interrupter capability The Mod V977 house a VME INTERRUPTER The module...

Page 13: ...nual MUT Mod V977 16 Channel I O Register Status A 27 08 2004 1 NPO Filename Number of pages Page 00118 01 V977X MUTX 01 V977_REV1 DOC 21 13 IRQ 1 IRQ7 FROM CHANNELS LOGIC FROM TEST CHANNEL LOGIC INTE...

Page 14: ...e accessible in D16 mode Table 4 1 Address Map for the Mod V977 ADDRESS REGISTER CONTENT ADDR DATA R W Base 0000 Base 0002 Base 0004 Base 0006 Base 0008 Base 000A Base 000C Base 000E Base 0010 Base 00...

Page 15: ...he relevant channel FLIP FLOP see 3 1 is set regardless the corresponding input connector s status 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 INPUT SET In Multihit pattern unit mode this register allows to...

Page 16: ...onds to one channel it reproduces the relevant input connector s logic level regardless the INPUT MASK register s status 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 INPUT READ 4 6 Single hit read register B...

Page 17: ...nt output is masked and no output signal is produced regardless the FLIP FLOPs status The output signal can be produced anyway via the relevant bit in the OUTPUT SET register see 4 8 15 14 13 12 11 10...

Page 18: ...egister clears the second FLIP FLOP see 3 1 of all channels 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MULTIHIT READ CLEAR 4 14 Test control register Base address 001A read write This register handles all...

Page 19: ...r Base address 0022 read write This register contains the STATUS ID that the V977 places on the VME data bus during the interrupt acknowledge cycle Bits 8 to 15 are meaningless 15 14 13 12 11 10 9 8 7...

Page 20: ...sent via FRONT PANEL signal is masked default setting 0 the GATE sent via FRONT PANEL signal is enabled incoming hits are accepted only as the GATE is active OR MASK read write 0 the OR and OR FRONT...