Document type:
Title:
Revision date:
Revision:
User's Manual (MUT)
Mod. V793, ICARUS Slow Control Module
16/01/01
0
NPO:
Filename:
Number of
pages:
Page:
00100/98:V793x.MUTx/00
V793_REV0.DOC
19
16
To modify any parameter, press the <S> key; the following Setting Menu will be displayed.
Fig. 3.2 – V793 Setting Menu with RS232
•
Press <1> to set the EN_BOARD lines status; write the pattern of inhibit (0…7FFFF
hexadecimal) then press <CR>; the LSB corresponds to the EN_BRD1 line status.
•
Press <2> to set the V791 test lines status; write the pattern of inhibit (0…3
hexadecimal) then press <CR>; the LSB corresponds to the CALIB_EVEN line status.
•
Press <3> to set the A764 test lines status; write the pattern of inhibit (0…3
hexadecimal) then press <CR>; the LSB corresponds to the ENABLE_EVEN line
status.
•
Press <4> to set the detector test lines status; write the pattern of inhibit (0…F
hexadecimal) then press <CR>; the LSB corresponds to the DRV_1 line status.
•
Press <5> to set DAC1; write the DAC value (0…FFF hexadecimal) then press <CR>;
FFF corresponds to +2.5 V.
•
Press <6> to set DAC2; write the DAC value (0…FFF hexadecimal) then press <CR>;
FFF corresponds to +2.5 V.
•
Press <7> to enable/disable the TEST_C line ; write 1/0 then press <CR>
•
Press <T> to test all the enable lines (front panel LEDs will light up sequentially); press
<CR> to exit from the test.
•
Pres <D> to test DACs operation; the DACs will generate a saw tooth output between
0 and 2.5 V; press <CR> to exit from the test.
The DACs values and EN_BRD lines status set by the User are stored in memory after
module power OFF.