background image

Purpose of this Manual 

This  document  is  the  A7030-AG7030  3kV/  1mA  (1.5W)  HV  Boards  user  manual;  it  contains  information  about  the 
installation, the configuration and the use of the board. 

Change Document Record 

Date 

Revision 

Changes 

30 March 2015 

PRELIMINARY Release 

9 April 2015 

Updated Overview and Channel status 

5 June 2015 

Updated Technical Specifications 

1 July 2015 

Update to new range 3kV/1mA 

30 July 2015 

Updated Channel specs p.5, set/mon parameters p.10 

10 November 2015 

Updated with 12, 24, 36 channel versions 

13 April 2016 

Updated pictures and table 2 

03 September 2019 

Updated Table1 

 

Symbols, abbreviated terms and notation 

T.B.D. 

Reference Documents 

 

Disclaimer 

No part of this manual may be reproduced in any form or by any means, electronic, mechanical, recording, or otherwise, 
without the prior written permission of CAEN SpA.  

CAEN  will  repair  or  replace  any  product  within  the  guarantee  period  if  the  Guarantor  declares  that  the  product  is 
defective due to workmanship or materials and has not been caused by mishandling, negligence on behalf of the User, 
accident or any abnormal conditions or operations. 

CAEN declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on 
behalf of the User. It is strongly recommended to read thoroughly the CAEN User's Manual before any kind of operation.

 

CAEN reserves the right to change partially or entirely the contents of this Manual at any time and without giving any 
notice. 

Disposal of the Product

 The product must never be dumped in the Municipal Waste. Please check your local regulations 

for disposal of electronics products. 

Made In Italy

 : We stress the fact that all the boards are made in Italy because in this globalized world, where getting 

the lowest possible price for products sometimes translates into poor pay and working conditions for the people who 
make them, at least you know that who made your board was reasonably paid and worked in a safe environment. (this 
obviously applies only to the boards marked "Made in Italy", we cannot attest to the manufacturing process of "third 
party" boards). 

 

 

 

 

 

 

 

 

 

Summary of Contents for A7030

Page 1: ...CAEN Tools for Discovery n Electronic Instrumentation Rev 5 Es A7030 AG7030 3kV 1mA 1 5W HV Boards Rev 7 03 September 2019...

Page 2: ...t is defective due to workmanship or materials and has not been caused by mishandling negligence on behalf of the User accident or any abnormal conditions or operations CAEN declines all responsibilit...

Page 3: ...cautions 9 Safety Terms and Symbols on the Product 9 Installation 9 3 Operating modes 10 Output control and monitoring 10 Channel STATUS Flag 10 Interlock protection 11 Grounding specifications 11 Saf...

Page 4: ...red via software if exceeded the relevant channel can be programmed either to turn off after a programmable trip time or to keep on providing the maximum allowed current this particular feature allows...

Page 5: ...esolution 1 V Ramp Up Ramp Down 1 500 Volt sec 1 Volt sec step Voltage Ripple 2 10 1000 Hz 15 mV typical 20 mV max 1000 Hz 5 mV typical 10 mV max VMon vs VOut Accuracy 3 4 typical 0 3 0 2 V max 0 3 1...

Page 6: ...CAEN Electronic Instrumentation A7030 AG7030 3kV 1mA 1 5W HV Boards 6 Front Panel Fig 1 A7030 family front panel 48 36 24 Multipin 24 SHV and 12 SHV channel version...

Page 7: ...ge VMAX common to all the channels Its value can be read out via software IMAX Function it allows to adjust the hardware maximum current IMAX common to all the channels Its value can be read out via s...

Page 8: ...CH26 37 CH23 48 CH25 7 CH32 17 CH29 28 CH31 38 CH28 49 CH30 8 CH37 18 CH34 29 CH36 39 CH33 50 CH35 9 CH42 19 CH39 30 CH41 40 CH38 51 CH40 10 CH47 20 CH44 31 CH46 41 CH43 52 CH45 21 RETURN 42 SAFETY L...

Page 9: ...rs To avoid electric shock or fire hazard do not operate this product with covers or panels removed Do Not Operate in Wet Damp Conditions To avoid electric shock do not operate this product in wet or...

Page 10: ...POn EN DIS Power On option which can be enabled or disabled If this option is enabled at Power On or after a Restart each channel is restored in the same condition defined by the Power parameter it wa...

Page 11: ...pin pin 21 on A AG7030 7030T pin 10 on A AG7030L if the board features SHV connectors skip this step Then it is necessary to configure the Interlock connector as follows contact open INTERLOCK voltage...

Page 12: ...not a working one The Connector Configurator allows to optimize the connection of the return and of DGND Earth The best configuration must be determined by the user upon application the optimal conne...

Page 13: ...ustomers including engineers scientists and technical professionals who all trust them to help achieve their goals faster and more effectively CAEN S p A CAEN GmbH CAEN Technologies Inc Via Vetraia 11...