background image

CAEN will repair or replace any product within the guarantee period if the Guarantor declares that the 
product is defective due to workmanship or materials and has not been caused by mishandling, 
negligence on behalf of the User, accident or any abnormal conditions or operations. 
 
 
 

 
CAEN declines all responsibility for damages or 
injuries caused by an improper use of the Modules due 
to negligence on behalf of the User. It is strongly 
recommended to read thoroughly the CAEN User's 
Manual before any kind of operation. 

 
 
 
 
 

 

 

This product must be installed by qualified personnel; the 3-phase EMC 
filter Mod. CAEN A3000NF does not support operation in hostile areas 
(magnetic field). 

 

CAEN reserves the right to change partially or entirely the contents of this Manual at any time and without 
giving any notice. 
 

Disposal of the Product

 

The product must never be dumped in the Municipal Waste. Please check your local 
regulations for disposal of electronics products. 

 

Summary of Contents for A3000NF

Page 1: ...Technical Information Manual MOD A3000NF 3 PHASE NOTCH FILTER MANUAL REV 4 18 June 2008 Revision n 4 NPO 00120 04 3000N MUTx 04...

Page 2: ...es due to negligence on behalf of the User It is strongly recommended to read thoroughly the CAEN User s Manual before any kind of operation This product must be installed by qualified personnel the 3...

Page 3: ...ES 8 1 9 ELECTRICAL SCHEME 8 2 SAFETY INFORMATION AND INSTALLATION REQUIREMENTS 9 2 1 INJURY PRECAUTIONS 9 2 1 1 General Recommendations 9 2 1 2 Caution 9 2 1 3 Grounding 10 2 1 4 Input ratings 10 2 1...

Page 4: ...me Number of pages Page 00120 04 3000N MUTx 04 A3000NF_REV4 DOC 13 4 FIG 1 6 EARTH CONNECTOR 7 FIG 1 7 FUSE HOUSING 8 FIG 1 8 MOD A3000NF ELECTRICAL SCHEME 8 FIG 2 1 AC SOURCE CONNECTION 11 FIG 2 2 PO...

Page 5: ...ns supply cable this filter does not support operation in hostile areas magnetic field 1 2 Technical description The CAEN Mod A3000NF is a two channel notch filter which must be used with the A3486 3...

Page 6: ...ter Packaging 19 wide 3U high Euro mechanics rack Depth 50 cm Weight 32 Kg AC input 3 phase 400 V 10 50 Hz see label below AC output 3 phase 400 V 50 Hz see label below Max Output Power 5000 W per sec...

Page 7: ...5 000 6106 Pin Phase 1 2 R 3 4 S 5 6 T 7 n c 1 7 Chassis EARTH Fig 1 6 Earth connector This section provides the Earth auxiliary reference and includes 1 Earth RADIALL R921921 type connector WARNING A...

Page 8: ...otch Filter for A3486 18 06 2008 4 NPO Filename Number of pages Page 00120 04 3000N MUTx 04 A3000NF_REV4 DOC 13 8 1 8 Fuses Fig 1 7 Fuse housing Type OMEGA type 10X38 8A 600V FF139280 3 Fuses per chan...

Page 9: ...s this exposes hazardous voltages WARNING THE A3000NF ACTUALLY OBSTRUCTS THE VERTICAL AIR FLOW THROUGH THE RACK 2 1 2 Caution The following safety precaution must be observed during all phases of oper...

Page 10: ...und wire firmly connected to an electrical ground safety ground at the power outlet For instruments designed to be hard wired to the supply mains the protective earth terminal must be connected to the...

Page 11: ...o an appropriate AC source The AC source voltage should be within the unit specification The A3000NF shall be connected to the AC source in the following way Fig 2 1 AC source connection 2 2 2 Initial...

Page 12: ...tage range and current required is specified in 1 4 Ensure that under heavy load the AC voltage supplied to the unit does not fall below the specifications described in 1 4 2 2 5 3 phase power supply...

Page 13: ...S IMPORTANT THAT WHENEVER ONLY ONE CHANNEL OF THE A3000NF IS USED THAT HAS TO BE THE LEFTMOST FROM REAR PANEL VIEW SEE 1 3 2 3 Maintenance No routine maintenance of the unit is required except for per...