3.
Ethernet Communication
The communication with the EnBOX unit is based on a 10/100/1000 Mbps
Ethernet link.
The factory network configuration and the “CAENels Device Manager”
software are described in the following sections.
3.1
IP Address Assignment
The device is shipped with default IP address, subnet mask, gateway and TCP-
IP communication port:
Parameter
Factory value
IP address
192.168.0.10
Subnet mask
255.255.255.0
Gateway
192.168.0.1
TCP/IP port
10001
For a point-to-point connection it is not necessary to use a twisted cable
because the used Ethernet link has an automatic detection of the communication
direction – i.e. auto-sensing.
To change the device network setup it is necessary to use the free
“CAENels
Device Manager”
software that can be downloaded from the CAENels website
. A briefly description of this software is given in next section.