background image

 
 
 
SoundCam - Software - Function Buttons          

 

 

Page 8 of 17 

 
Example: 
two noise sources (2,5 kHz and 5 kHz) 
set cursors e.g. at 1728 Hz and 3998 Hz -> you 
see just the noise source 2,5 kHz 

 

 

 

 
Example : 
two noise sources (2,5 kHz and 5 kHz) + 
Dropping paper clip (Impulse - see red marker 
in sonogram) 
 
 

 

 

 

 
Paper clip hits the ground 
Move cursor short before first impulse and 
press arrow button in the timeline until the 
sound level increases -> new noise source 
comes up (the paper clip hits the ground)  
 
 

 

 

 

 
Reduce the dynamic range to see the place of 
impact 
 
 
This “step by step method” is perfect for high 
dynamic events e.g. S&R, for structure, 
material and component tests,… 

 

 

 

 

 

 

 

Summary of Contents for SoundCam

Page 1: ...Manual SoundCam...

Page 2: ...s LED Turn on Press Hold 2 sec status LED flashes while booting and turns green when finished Turn Off Press Hold until all battery level 4 LEDs are off Check battery level Press short 2 USB connector...

Page 3: ...ware Starter Guide 1 Start measurement 2 Settings 3 Shut system down 4 Profile 5 Saved measurements Press 1 start measurement Start 1 Distance between mic and surface 2 Scaling 3 Frequency filter 4 Re...

Page 4: ...ording 2 Play recording 3 Time navigation 4 Take snapshot online offline 5 Create video 6 Save video 7 Close window Press settings Press button Plug your USB stick not included in delivery content int...

Page 5: ...m Software Starter Guide Page 5 of 17 Mark files Video are webm can be opened by all internet explorers Snapshot are png Copy on your USB stick Copy is done Close window Remove USB stick and enjoy on...

Page 6: ...box Scaling settings Choose your scaling by clicking on the first dark blue box auto Max found in the pictures is used as maximum Smart Removes background noise Average level of the picture is calcula...

Page 7: ...range you want to see in the acoustic picture using the double slider You can also type in numbers by clicking into the Max Freq or Min Freq box Attention Higher frequencies can be localized more ac c...

Page 8: ...Dropping paper clip Impulse see red marker in sonogram Paper clip hits the ground Move cursor short before first impulse and press arrow button in the timeline until the sound level increases new noi...

Page 9: ...Select the time you want to record using the drop down menu Attention Longer record times take longer to process e g saving opening and create a video Scroll your measurement s timeline After measurem...

Page 10: ...utton to delete the current selected marker Create video Use the first two buttons to place the start and end point for the video if you do not want to create a video over the whole timeline The third...

Page 11: ...Zoom in zoom out optical picture double click on the optical picture Zoom inside sonogram Click long in the sonogram XYZ pops up Press X for min max of the x axis Press Y for min max of the y axis Pr...

Page 12: ...17 E g press Y for min max of the y axis choose the max value by and press max limit Press outside the window to close the window or press max limit to set the min limit After pressing max limit the m...

Page 13: ...SoundCam Software system settings 1 Camera and beam settings 2 Copy menu 3 Info and update 4 Folder setting 5 Button settings 6 Profile settings 1 Camera and beam settings 1 Beam speed 2 Camera resolu...

Page 14: ...SoundCam Software system settings Page 14 of 17 Info and update System information Update your system Select your SoundCam update swupd your system will be updated...

Page 15: ...SoundCam Software system settings Page 15 of 17 Folder settings Activate measurement series and put in measurement series name Button settings Select a function from the pull down menu...

Page 16: ...ettings 1 Delete profile 2 Load profile from the pull down menu load a profile all settings are defined 3 Restore defaults 4 New profile Find the latest software up to date FAQ and much more on our we...

Page 17: ...0 5241 21142 0 Fax 49 0 5241 21142 29 info cae systems de www cae systems de Gesch ftsf hrer Dipl Ing MBA Nico Zurm hlen Handelsregister Gesellschaft mit Sitz in G tersloh Amtsgericht G tersloh HRB 8...