TR-MAN-1100
Operator's Manual - Micro-Travellers
Page 22 of 68
Cadman Power Equipment ▪ BOX 100, Courtland, Ontario, Canada N0J-1E0 ▪ Phone: 519-688-2222 ▪ Fax: 519-688-2100 ▪ www.cadmanpower.com
Step 6
Once the display screen is done loading, it will tell you to set the speed using buttons
as shown in the figure below. Set the desired retrieval speed by pushing the upper
button beside the display. You can decrease the retrieval rate by pressing the lower
button
Figure 24 - Adjust Retrieval Speed
img-00713
Retrieval speed can be confirmed by measuring the amount of hose
retrieved in one minute using a measuring tape and a wax marker.
Step 7
Once the machine starts to retrieve the hose you must test the Shut-off System to
verify it is in working order. Rotate the shut-off bar to actuate the Shut-off System. If
the retrieval stops, release the shut-off bar to continue the retrieval. If not, stop use of
the machine and contact
Cadman Power Equipment Limited
or your local dealer for
further instructions.
Figure 25 - Verify Shut-off System
img-00749