TR-MAN-1100
Operator's Manual - Micro-Travellers
Page 21 of 68
Cadman Power Equipment ▪ BOX 100, Courtland, Ontario, Canada N0J-1E0 ▪ Phone: 519-688-2222 ▪ Fax: 519-688-2100 ▪ www.cadmanpower.com
Step 3
GRADUAL
pressurization of the system may now begin. Keep the pressure low
(under 20 psi [138 bar]) until
ALL
air is purged from the system and a steady stream is
flowing from the sprinkler nozzle.
AFTER
all the air is purged from the system,
pressure may be slowly increased to the maximum operating pressure of 120 psi
(8.3 bar).
Now you are ready to begin the hose retrieval.
Step 4
Before the power is turned on, engage the drive system. The clutch has angled
faces to allow for easy meshing if the power is already on and the drive is engaged
while it is running. When the drive faces line up, the clutch will engage.
Figure 22 - Engage Drive System
img-00744
Step 5
Pull the power switch (red button) to turn on the power to the unit.
Figure 23 - Control Panel
img-00712