2016 Cadex Electronics Inc. 

individual cells of an unknown nature with a series and parallel 
connection. Not all Li-ion cells are suited for multi-cell packs. 
Only cells that meet tight voltage and capacity tolerances can be 
used for series and parallel connection. Mismatched packs are 
subject to overcharge resulting in venting with flame and fire. 
Check with the cell manufacturer to see if the cells are suitable for 
multi-cell packs. 
In the past, single Li-ion cells were only available to authorized 
battery manufacturers. Today, imports are becoming readily 
available and often fall into the hands of the inexperienced. While 
most brand name cells are equipped with an internal cell 
disconnect that permanently opens the current path on high 
pressure, some brands do not provide this safeguard. Many 
brands don’t use a separator that shuts down the battery when 
high temperatures are reached. The internal safety features are 
omitted for cost reasons. 

Please follow the following guidelines when charging and 
discharging lithium-ion cell(s) and packs. Failing to follow 
these rules could result in venting with flame, explosions, fire, 
and personal injury. 

x

 

Never connect cells in parallel and/or series that are not 
designed for that purpose. A cell mismatch may overcharge 
and vent with flames 

x

 

Never charge or discharge the battery without connecting a 
working protection circuit. Each cell must be monitored 
individually and the current disconnected if an anomaly 
occurs. 

x

 

Never leave the battery unattended while under charge or 
discharge. 

 

Always attach a temperature sensor when charging and 
discharging the battery. The temperature sensor must 
disconnect the current on excess temperature. 

 

Only connect cells that are matched and have identical state-of-
charge. 

 

Pay special attention when using an unknown brand. Not all 
brands contain intrinsic safety features that protect the cell 
when stressed. 

 

During experiments, place the test battery into a well-
ventilated fireproof container. 

 

Summary of Contents for BatteryStore C5100B

Page 1: ...Cadex C5100B Battery Tester User Guide...

Page 2: ...p is accurate and up to date Cadex Electronics Inc does not warrant or guarantee the accuracy of the contents of this manual and Online Help Further Cadex makes no warranties either expressed or impli...

Page 3: ...the equipment not expressly approved by Cadex Electronics Inc To obtain service contact service cadex com or Canada 1 604 231 7777 USA Toll Free 800 565 5228 or Europe 49 0 6105 975 11 0 To ensure th...

Page 4: ...Equipment WEEE in the European Union 10 Section 2 Introduction 11 The Cadex C5100B Battery Tester Package 11 Cadex C5100B Battery Tester Features 12 Section 3 Battery Testing 14 Available Programs 14...

Page 5: ...t where it is easily accessible Use of Equipment The Cadex C5100B Battery Tester is designed with adequate safeguards to protect users from shock and other hazards when used as specified within this d...

Page 6: ...F and 50 C 122 F Stop service if battery becomes very hot The temperatures cited here are the battery temperatures not the ambient temperatures Fast charging outside this temperature range may damage...

Page 7: ...peratures are reached The internal safety features are omitted for cost reasons Please follow the following guidelines when charging and discharging lithium ion cell s and packs Failing to follow thes...

Page 8: ...ials and workmanship for a period of two 2 years from the original purchase date The warranty does not cover Damage caused by abusive operation negligence accident or improper installation Damage caus...

Page 9: ...ervice contact Cadex Technical Support at Canada 1 604 231 7777 USA Toll Free 800 565 5228 or Europe 49 0 6105 975 11 0 or service cadex com If the tester is not covered by warranty the representative...

Page 10: ...be required to take adequate corrective measures The equipment is designed with adequate safeguards to protect the user from shock and other hazards when used as specified within this document If the...

Page 11: ...Health SoH of the battery The Cadex C5100B Battery Tester Package The Cadex C5100B Battery Tester package contains the following items Cadex C5100B Battery Tester unit Universal Configurable Battery A...

Page 12: ...y Tester has three LEDs Run yellow Ready green and Fail red The front panel also contains three buttons Test Charge and Cycle and two scroll buttons Test Performs battery rapid tests using Cadex Quick...

Page 13: ...r User Guide 13 2016 Cadex Electronics Inc Serial port Used to connect to an Optional Receipt Printer AC Power Inlet Attach to power outlet USB Port Used to connect to a computer for use with BatteryS...

Page 14: ...battery within 30 seconds and QuickSort 4 0 can test a battery in 4 minutes Q codes required for Cadex s QuickSort 3 0 is only available through BatteryStore Please refer to Cadex C5100B BatteryStore...

Page 15: ...gram key Charge Test or Cycle for two seconds The C5100B will display 3 70V Boost Selected and then Select Voltage 4 Scroll to the battery s nominal voltage with and press the Test key to select 5 The...

Page 16: ...test result will appear on the screen 10 Disconnect the battery to clear the test result screen Good Battery A battery for which the QuickSort 4 0 algorithm has determined to have a capacity higher t...

Page 17: ...Press Charge and confirm the voltage and the capacity entered previously by pressing the Test key The C5100B will perform a fast charge 9 When the battery has finished charging the Ready LED will be...

Page 18: ...ster Ensure battery adapter is NOT installed 2 There should be no LEDs on and LCD should display Install Battery Adapter 3 Press the Test key for 2 seconds and the C5100B will display System Setup Tar...

Page 19: ...timeframe 3150 Thermistor Failure Unable to read temperature 3159 Hot Battery Battery is too hot to start processing 3160 Bad Fuse Or Driver No current for more than 30 seconds 3201 Cold Battery Batt...