PANEL ELEMENT
DESCRIPTION
Exchanger fan: active.
-
Alarm: active.
Fig. 36 - LCD control display
LEGEND
1
Time
2
Power
3
State
4
Message
5
Temperature
11.4
USER MENU
By once pressing P3 key you can hace access to user parameter controlling. To let them slide press P5 and P6
keys. They are:
POS.
REFERENCE
DESCRIPTION
1
FAN ADJUST
(supplementary)
Press once P3: Nr2 fan appears (for one ducting) or Nr2 and Nr3 fans appears (for double
ducting). See
2
SET CLOCK
Set date and time. The board is provided with a lithium battery which enables a clock
autonomy of 3/5 years. See
.
3
SET CHRONO
Press once P3: “CHRONO ENABLE” appears. Press P3 again and with P1 and P2 put in “OFF”
or “ON”. For daily, week-end or weekly programming, see
. CAUTION: do not active if STAND-BY function is active!
4
SELECT
LANGUAGE
Press once P3 key and with P1 and P2 keys select the desired language.
5
STAND-BY MODE
It activates a function which, if the set ambient temperature has been exceeded for more
then 10 minutes, start the switching off phase up. If the ambient temperature has fall at
more than 2°C, the stove will restart automatically up, starting from
Press once P3 key and with P1 and P2 keys put in “OFF” or “ON”. CAUTION: do not activate
if CHRONO function is active!
6
BUZZER MODE
(audio alarm)
Press once P3 key and with P1 and P2 keys put in “OFF” or “ON”.
7
INITIAL LOAD
When the stove has its first ignition, the auger is completely empty. If it should be necessary
do a precharge by pressing P3 key, then P1 key for starting up and P4 key for stop.
8
STOVE STATE
It shows all parameters connected to the stove state: this is a menu for the Authorized
Techinician
9
TECHNICA SETTING
Only for the Authorized Technician.
10
FLAME SETTING
It enables to set the flame dipending on the draught of the chimney flue.