19
VENUS PLUS - GIOIA-2
EN
Fig. 35 - Ducting system example
•
If the stove is not fitted with ducting system, it provide a hot air capacity ranging from a minimum of 50 m
3
/h
to a maximum of 162 m
3
/h with a temperature ranging between 83°C and 108°C, data valid for each upper
outlet and the central room fan.
•
For the ducting system, we recommend using a pipe with a maximum length of 6 mt and up to three 90°
elbows in order to maintain hot air temperature.
•
Use pipes with smooth internal surface and a diameter of 80 mm.
•
Fit the pipe with insulating material if it passes through a cold wall.
•
The outlet must be protected by a grid with wide mesh and a minimum total surface area of 24 cm
2
.
•
If the pipes used are longer than 6 mt, the air capacity ranges from a minimum of 30 m
3
/h to a maximum of
80 m
3
/h and the temperature from 50°C to 80°C. (These values refer to the laboratory used for the tests. The
room where the stove is installed may register different values both in terms of capacity and temperature).
•
If you wish to increase air capacity, install at the end of the pipe a small wall-mounted fan with a capacity
exceeding 80 m
3
/h. The installation must be carried out by an authorised technician.
•
According to the factory parameters, 1/3 of the generated heat is conveyed into the room where the stove
is installed, while the remaining 2/3 are conveyed through the right and left ducting pipe system.
•
Balance heat output with air capacity to obtain the best performance (see
The operation above must be carried out by an authorised technician.
11
USE
11.1
ATTENTION
This appliance must not be used by people (childreen included) with reduced mobility,
psycological deseases or without experience and knowledge except in case of supervision
or instruction about the use of the appliance by people responsible for their safety.
Childreen must be constantly overseen in order to assure that they do not play with the
appliance.
The stove is provided with a hand rejector: this rejector can be removed exclusively by the
stove manufacturer or by the Technical Assistance Service.