new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
34
14 TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COM-
MISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE)
Manufacturer
CADEL srl - Via Foresto Sud 7 - 31025 Santa Lucia di Piave (TV) - Italy
Trademak: model identifier
CADEL: RIVER IDRO 23 T2 - RIVER IDRO 23 H2O T2 - MAYA IDRO 24 T2
FREEPOINT: TESIS 23 AIRTIGHT T2
PEGASO:
Description
Pellet stove
Indirect heating functionality
Yes
Direct heat output
4,4 kW
Indirect heat output
18 kW
CPR harmonised standard
EN 14785
Notified body
KIWA CERMET ITALIA S.P.A.(N.B.0476)
Preferred fuel (unique)
Compressed wood with moisture content < 12 %
YES
Wood logs with moisture content ≤ 25 %
NO
Other woody biomass
NO
η
s
88
%
EEI
130
-
Energy Efficiency Class (A++ to G scale)
A++
Space heating emissions at nominal heat output
PM (al 13% O
2
)
14
mg/Nm
3
OGC (al 13% O
2
)
2
mg/Nm
3
CO (al 13% O
2
)
136
mg/Nm
3
NO
x
(al 13% O
2
)
99
mg/Nm
3
Space heating emissions at minimum heat output
Only required if correction factors F(2) or F(3) are applied
PM (al 13% O
2
)
18
mg/Nm
3
OGC (al 13% O
2
)
3
mg/Nm
3
CO (al 13% O
2
)
150
mg/Nm
3
NO
x
(al 13% O
2
)
94
mg/Nm
3
Heat output
Nominal heat output (P
nom
)
22,4
kW
Minimum heat output (indicative) (P
min
)
4,9
kW
Useful efficiency (NCV as received)
Useful efficiency at nominal heat output (η
th,nom
)
92
%
Useful efficiency at minimum heat output (indicative)
(η
th,min
)
96,7
%
Auxiliary electricity consumption
At nominal heat output (el
max
)
0,117
kW
At minimum heat output (el
min
)
0,076
kW
In standby mode (el
sb
)
0,002
kW
Type of heat output/room temperature control (select
one)
Single stage heat output, no room temperature control
NO
Two or more manual stages, no room temperature
control
NO
With mechanic thermostat room temperature control
NO
With electronic room temperature control
NO
With electronic room temperature control plus day
timer
NO
With electronic room temperature control plus week
timer
YES
Other control options (multiple selections possible)
Room temperature control, with presence detection
NO
Room temperature control, with open window detec-
tion
NO
With distance control option
YES
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable) (P
pilot
)
N.A.
kW
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the
product.
Issue date: 13.09.2022