Per each pellets supply, check the probable presence of meal, sawdust and other remanins on the hopper bottom. If present, they
must be removed with the aid of a vacuum cleaner (see
).
11.4 ASH DRAWER CLEANING RIVER IDRO - MIRA - TESIS
Press door “H” to the bottom right and open it. Turn the handle of door “G” to the right and open it downwards.
Pull out and empty ash drawer “D”. Remove any ash residue from the compartment before reinserting the drawer. Experience and
pellet quality will determine the frequency of the ash drawer cleaning. In any case, it is advisable not to exceed 2 or 3 days.
When cleaning the ash drawer, we recommend removing part “C” near the brazier and using a vacuum cleaner nozzle to remove
any ash build-up.
Fig. 18 - Drawer removal
Fig. 19 - Brazier removal
11.5 ASH DRAWER CLEANING MAYA
Lift part “C” from its place and remove brazier “B”. Use the vacuum nozzle to clean away any ash from the area under the brazier.
We recommend performing this operation every 2-3 days depending on what type of pellet is being used.
Open the panel “H”. Turn the handle of door “G” to the right and open it by moving it downwards.
Remove and empty ash pan “D”. Wipe away any residual ash before reinserting the pan. Your experience and the quality of the
pellets will determine the ash pan cleaning frequency. However, it is recommended not to exceed 7 days. After removing and
emptying the ash pan “D” also clean the lower part of the compartment (see arrow “Q”).
Fig. 20 - Brazier removal
Fig. 21 - Drawer removal