background image

Stufe a pellet

16

Fig. 14 - Active eco 1

Fig. 15 - Active eco 2

Fig. 16 - Active eco 3

On the upper display the minutes for the Eco Stop countdown are shown. The flame goes to P1, where it remains until the set "

Off Time Eco

" time is over and, if conditions are still met, it switches to the switch-off process. The ECO switch-off countdown is 

reset if one of the devices resumes recalling power.

When the switch-off procedure begins, the panel shows: Off - Active Eco - small flashing flame (see 

Fig. 17

).

When the stove is switched off, the panel shows active OFF-ECO with the flame icon off.

For an ECO switch on, the following conditions must be met simultaneously:

•  Room probe -1°C or external thermostat with closed contact (for at least 20" to avoid false recalls).

•  After 5 minutes from the beginning of the switch-off procedure.

9.15  SLEEP FUNCTION (MAIN MENU)

The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the product must 

switch off.

To set the Sleep function act as follows:

•  Enter MENU

•  Scroll to SLEEP with the <> arrows

•  Press Menu

•  With the + - keys adjust the desired shutdown time.

The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day (I can therefore 

delay the shutdown for up to a maximum of 23 hours and 50 minutes).

Fig. 17 - Sleep

If the SLEEP function is active with the TIMER active the first has priority over the latter, therefore the boiler will not switch off at 

the time set on the timer but instead by the time established by the sleep function, even if later than the time set on the timer.

9.16  PELLETS RECIPE (SEE SECTION J SETTINGS MENU A PAG. 10)

This function is for adapting the stove to the pellets that are being used. In fact, as there are several types of pellets on the market, 

boiler operation is extremely variable depending on the fuel quality. In the event the pellets tend to clog the brazier due to an 

excessive load of fuel or in the event the flame is always high even at low powers and, vice versa if the flame is low one can decre-

ase/increase the amount of pellets in the brazier:

The available values are:

-30= 30% reduction with respect to the default setting.

-25= 25% reduction with respect to the default setting.

-20= 20% reduction with respect to the default setting.

-15 = 15% reduction with respect to the default setting.

-10= 10% reduction with respect to the default setting.

-5= 5% reduction with respect to the default setting.

0= No variation.

+5= 5% increase with respect to the default setting.

+10 = 10% increase with respect to the default setting.

+15 = 15% increase with respect to the default setting.

9.17  SMOKE RPM VARIATION (SEE SECTION I SETTINGS MENU A PAG. 10)

If the installation presents difficulties for smoke evacuation (no draught or no pressure in the duct), the smoke and ash expulsion 

speed can be increased. This change resolves all the potential problems related to pellets clogging in the brazier and deposits 

forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes. The values available are 

from -27% to +27% with variations of 3 points at a time. The variation in negative can be used in case the flame is too low.

Summary of Contents for SWEET3 7

Page 1: ...served Tuttiidirittiriservati USER MANUAL Pellet Stove SWEET3 7 7 0 PERLA3 7 7 0 CRISTAL3 7 7 0 7 0 UP ONE AIRTIGHT BEAM AIRTIGHT ACCENT AIRTIGHT SHARP AIRTIGHT LEE AIRTIGHT CHROME 5 7 AIRTIGHT ROUND...

Page 2: ...correctionfactorsF 2 orF 3 areapplied PM al 13 O2 20 mg Nm3 OGC al 13 O2 4 mg Nm3 CO al 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom 5 5 kW Minimum heat output indicat...

Page 3: ...correctionfactorsF 2 orF 3 areapplied PM al 13 O2 20 mg Nm3 OGC al 13 O2 4 mg Nm3 CO al 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicativ...

Page 4: ...correctionfactorsF 2 orF 3 areapplied PM al 13 O2 20 mg Nm3 OGC al 13 O2 4 mg Nm3 CO al 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicativ...

Page 5: ...minimum heat output OnlyrequiredifcorrectionfactorsF 2 orF 3 areapplied PM al 13 O2 20 mg Nm3 OGC al 13 O2 4 mg Nm3 CO al 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom...

Page 6: ...fers to highlight the main components that can be found in the device and indica tions on how to separate and dispose of them correctly when no longer used More specifically the electric and electroni...

Page 7: ...le The table below illustrates the possible components that the packaging is made of and the relative instructions for correct dispo sal DESCRIPTION CODE MATERIAL SYMBOL DIRECTIONS FOR COLLECTION WOOD...

Page 8: ...PE SEE SECTION J SETTINGS MENU A PAG 10 16 9 17 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 10 16 9 18 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TECHNICIANS ONLY SEE SECTION K SETTINGS MENU A P...

Page 9: ...2014 30 EU Electromagnetic Compatibility 2011 65 EU ROhS Hereby CADEL S r l declares that the radio equipment type Easy Connect Plus Navel Stand Alone is in compliance with Directive 2014 53 EU Read c...

Page 10: ...al steel glass etc thatalsoprotectsthefrontpartfromanyfallingburntparticlesduringcleaning Theelectricalcablemustnotgetintouchwiththefumeexhaustpipeandnorwitheveryotherpart ofthestove The user or whoev...

Page 11: ...he use and maintenance manual are observed and therefore the product is used correctly Thereplacementoftheentiresystemortherepairofoneofitscomponentsdoesnotextendtheguaranteeperiod andtheoriginal expi...

Page 12: ...THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compliance with laws related to safety and environme...

Page 13: ...your local Council or Public Authority competent to issue the relevant permits 8 WIFI BLUETOOTH CONNECTION 8 1 EASY CONNECT PLUS ProcedureifonlyvalidformodelswithEASYCONNECTPLUSWi Fitechnology Fig 2 E...

Page 14: ...amage to property or in the event of failedoperation The Wi Fi module uses the domestic Wi Fi network ensure there is enough coverage in the place of installation Fig 4 NAVELSTANDALONEmodule Fig 5 App...

Page 15: ...ndurance in the combustion chamber cannot be guarantee Oily plant waste and lacquers can cause smells and smoke during the first working hours it is advisable to ventilatetheroombecausetheycouldbenoxi...

Page 16: ...witched off k Chimney Sweep Function activated only when the boiler is switched on for field emissions test l Technical Menu a Language To select the language act as follows Press the menu button Scro...

Page 17: ...the arrows Press menu to confirm Scroll to OffTime Eco using the arrows Press menu to confirm Enter the minutes with the keys Press menu to confirm and esc to exit h Pellet Recipe To change the recipe...

Page 18: ...START UP We remind you that the first ignition must be carried out by a specialized and authorixed technician who will check that all is installed in compliance with current regulations and checks the...

Page 19: ...s reached The flue fan is set to its highest value which it keeps until the requested temperature is reached plus a safety time of 10 additional minutes After that if the fume temperature has decrease...

Page 20: ...to 1 If 5 notches appear the stove has a flame power equal to 5 If the notches flash automatic cleaning is under way Fig 12 Display Fig 13 Powerlevels 9 11 PROGRAMMED MODE TIMER MAIN MENU Settingthecu...

Page 21: ...ill not switch off use this shutdown time for example when the next day is programmed to continue from 00 00 If the shutdown time is not already memorised it proposes a start up time in 10 minutes Ati...

Page 22: ...the timer but instead by the time established by the sleep function even if later than the time set on the timer 9 16 PELLETS RECIPE SEE SECTION J SETTINGS MENU A PAG 10 Thisfunctionisforadaptingthes...

Page 23: ...ules quantity Humidpelletscauseabadcombustionandrunning sopleaseassureyouthattheyarestoredindryplacesand faratleastonemeterfromthestoveand oranyothersourceofheat It is advisable to try different type...

Page 24: ...teitsairtightsealing vediFig 22 10 4 VENTILATION The stove is endowed with a ventilation system The air blown from fans keeps the appliance at a low temperature range in order to avoid high stresses t...

Page 25: ...AFETY DEVICES The product is supplied with the following safety devices 11 2 PRESSURE SWITCH It controls pressure in the fume duct It blocks the pellet feed screw in the following instances clogged ex...

Page 26: ...the boiler on or in the start up stage when the boiler is powered again it goes back to the previous operating condition with the following procedure 1 It performs a cooling phase to the maximum 2 Per...

Page 27: ...ause is still present If this is the case the warning will be shown again otherwise the stove will switch to the OFF position If the warning is still present contact a service centre 12 ROUTINE MAINTE...

Page 28: ...f a vacuum cleaner see Fig 28 Fig 27 Hoppercleaning 12 4 FUME PIPES ANNUAL CLEANING Clean annually from soot with brushes The cleaning operation must be executed by a specialized stove repairer who wi...

Page 29: ...from the flue or leave the door slightly open humidity damages the ignition resistance over time 13 IN CASE OF ANOMALY 13 1 PROBLEM SOLVING Before of every Authorized Technician intervention the same...

Page 30: ...by a foreign object for example nails Clean the auger The auger geared motor is out of order Replace the geared motor Check if on the display there is an ACTIVE ALARM Have the stove checked The fire e...

Page 31: ...erature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume pipes Contact an e...

Page 32: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...