background image

Stufe a pellet

6

•  Variations in colour of the painted or ceramic/serpentine parts and craquelure ceramics as they are natural characteristics of 

the material and product use. 

•  Masonry work.

•  Plant parts (if present) not supplied by the manufacturer.

Any technical interventions on the product to eliminate the above-said defects and consequent damages must be agreed upon 

with the Technical Assistance Centre, who reserves the right to accept the relative appointment or not. However, said interventions 

will not be carried out under warranty but as technical assistance to be granted at part of any eventual and specific agreed condi-

tions and in accordance with the fee in force for the work to be carried out.

The user will also be charged for any costs incurred to remedy the incorrect technical interventions, tampering or damage to the 

appliance, not attributable to original faults.

Save for the legal or regulatory limits, the guarantee does not cover the containment of atmospheric and acoustic pollution.

The company declines all liability for any damage which may be caused, directly or indirectly, to persons, animals 

or objects as a consequence of non compliance with any prescription specified in the manual, especially warnings 

regarding installation, use and maintenance of the appliance.

SPARE PARTS

For each repair or adjustment which should be necessary, please contact the dealer where you purchased your stove or your nea-

rest Technical Assistance Service, specifying:

•  Appliance model

•  Serial number

•  Type of problem

Use only original spare parts which you can find at our Technical Assistance Services. 

WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT

The owner is the sole party responsible for demolishing and disposing of the product. This must be performed in compliance with 

laws related to safety and environmental protection in force in his/her country.

At the end of its working life, the product must not be disposed of as urban waste.

It must be taken to a special differentiated waste collection centre set up by the local authorities or to a retailer that provides this service.

Separating and recycling prevents potential negative effects on the environment and health (often caused by inappropriately 

disposing of product parts). It also allows materials to be recovered in order to obtain significant savings in energy and resources.

7.1 

INFORMATION FOR MANAGEMENT OF ELECTRIC AND ELECTRONIC APPLIANCE WASTE CON-

TAINING BATTERIES OR ACCUMULATORS

Fig. 1 - Waste disposal

This symbol, which is used on the product, batteries, accumulators or on the packaging or documents, means that at the end of its 

useful life, this product, the batteries and the accumulators included must not be collected, recycled or disposed of together with 

domestic waste.

Improper management of electric or electronic waste or batteries or accumulators can lead to the leakage of hazardous substances 

contained in the product. For the purpose of preventing damage to health or the environment, users are kindly asked to separate 

this equipment and/or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal 

waste service It is possible to ask your local dealer to collect the waste electric or electronic appliance under the conditions and 

following the methods provided by national laws transposing the Directive 2012/19/EU.

Separate waste collection and recycling of unused electric and electronic equipment, batteries and accumulators helps to save 

Summary of Contents for SWEET3 7

Page 1: ...served Tuttiidirittiriservati USER MANUAL Pellet Stove SWEET3 7 7 0 PERLA3 7 7 0 CRISTAL3 7 7 0 7 0 UP ONE AIRTIGHT BEAM AIRTIGHT ACCENT AIRTIGHT SHARP AIRTIGHT LEE AIRTIGHT CHROME 5 7 AIRTIGHT ROUND...

Page 2: ...correctionfactorsF 2 orF 3 areapplied PM al 13 O2 20 mg Nm3 OGC al 13 O2 4 mg Nm3 CO al 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom 5 5 kW Minimum heat output indicat...

Page 3: ...correctionfactorsF 2 orF 3 areapplied PM al 13 O2 20 mg Nm3 OGC al 13 O2 4 mg Nm3 CO al 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicativ...

Page 4: ...correctionfactorsF 2 orF 3 areapplied PM al 13 O2 20 mg Nm3 OGC al 13 O2 4 mg Nm3 CO al 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom 7 kW Minimum heat output indicativ...

Page 5: ...minimum heat output OnlyrequiredifcorrectionfactorsF 2 orF 3 areapplied PM al 13 O2 20 mg Nm3 OGC al 13 O2 4 mg Nm3 CO al 13 O2 238 mg Nm3 NOx al 13 O2 140 mg Nm3 Heat output Nominal heat output Pnom...

Page 6: ...fers to highlight the main components that can be found in the device and indica tions on how to separate and dispose of them correctly when no longer used More specifically the electric and electroni...

Page 7: ...le The table below illustrates the possible components that the packaging is made of and the relative instructions for correct dispo sal DESCRIPTION CODE MATERIAL SYMBOL DIRECTIONS FOR COLLECTION WOOD...

Page 8: ...PE SEE SECTION J SETTINGS MENU A PAG 10 16 9 17 SMOKE RPM VARIATION SEE SECTION I SETTINGS MENU A PAG 10 16 9 18 CHIMNEY SWEEP FUNCTION FOR MAINTENANCE TECHNICIANS ONLY SEE SECTION K SETTINGS MENU A P...

Page 9: ...2014 30 EU Electromagnetic Compatibility 2011 65 EU ROhS Hereby CADEL S r l declares that the radio equipment type Easy Connect Plus Navel Stand Alone is in compliance with Directive 2014 53 EU Read c...

Page 10: ...al steel glass etc thatalsoprotectsthefrontpartfromanyfallingburntparticlesduringcleaning Theelectricalcablemustnotgetintouchwiththefumeexhaustpipeandnorwitheveryotherpart ofthestove The user or whoev...

Page 11: ...he use and maintenance manual are observed and therefore the product is used correctly Thereplacementoftheentiresystemortherepairofoneofitscomponentsdoesnotextendtheguaranteeperiod andtheoriginal expi...

Page 12: ...THE CORRECT DISPOSAL OF THE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This must be performed in compliance with laws related to safety and environme...

Page 13: ...your local Council or Public Authority competent to issue the relevant permits 8 WIFI BLUETOOTH CONNECTION 8 1 EASY CONNECT PLUS ProcedureifonlyvalidformodelswithEASYCONNECTPLUSWi Fitechnology Fig 2 E...

Page 14: ...amage to property or in the event of failedoperation The Wi Fi module uses the domestic Wi Fi network ensure there is enough coverage in the place of installation Fig 4 NAVELSTANDALONEmodule Fig 5 App...

Page 15: ...ndurance in the combustion chamber cannot be guarantee Oily plant waste and lacquers can cause smells and smoke during the first working hours it is advisable to ventilatetheroombecausetheycouldbenoxi...

Page 16: ...witched off k Chimney Sweep Function activated only when the boiler is switched on for field emissions test l Technical Menu a Language To select the language act as follows Press the menu button Scro...

Page 17: ...the arrows Press menu to confirm Scroll to OffTime Eco using the arrows Press menu to confirm Enter the minutes with the keys Press menu to confirm and esc to exit h Pellet Recipe To change the recipe...

Page 18: ...START UP We remind you that the first ignition must be carried out by a specialized and authorixed technician who will check that all is installed in compliance with current regulations and checks the...

Page 19: ...s reached The flue fan is set to its highest value which it keeps until the requested temperature is reached plus a safety time of 10 additional minutes After that if the fume temperature has decrease...

Page 20: ...to 1 If 5 notches appear the stove has a flame power equal to 5 If the notches flash automatic cleaning is under way Fig 12 Display Fig 13 Powerlevels 9 11 PROGRAMMED MODE TIMER MAIN MENU Settingthecu...

Page 21: ...ill not switch off use this shutdown time for example when the next day is programmed to continue from 00 00 If the shutdown time is not already memorised it proposes a start up time in 10 minutes Ati...

Page 22: ...the timer but instead by the time established by the sleep function even if later than the time set on the timer 9 16 PELLETS RECIPE SEE SECTION J SETTINGS MENU A PAG 10 Thisfunctionisforadaptingthes...

Page 23: ...ules quantity Humidpelletscauseabadcombustionandrunning sopleaseassureyouthattheyarestoredindryplacesand faratleastonemeterfromthestoveand oranyothersourceofheat It is advisable to try different type...

Page 24: ...teitsairtightsealing vediFig 22 10 4 VENTILATION The stove is endowed with a ventilation system The air blown from fans keeps the appliance at a low temperature range in order to avoid high stresses t...

Page 25: ...AFETY DEVICES The product is supplied with the following safety devices 11 2 PRESSURE SWITCH It controls pressure in the fume duct It blocks the pellet feed screw in the following instances clogged ex...

Page 26: ...the boiler on or in the start up stage when the boiler is powered again it goes back to the previous operating condition with the following procedure 1 It performs a cooling phase to the maximum 2 Per...

Page 27: ...ause is still present If this is the case the warning will be shown again otherwise the stove will switch to the OFF position If the warning is still present contact a service centre 12 ROUTINE MAINTE...

Page 28: ...f a vacuum cleaner see Fig 28 Fig 27 Hoppercleaning 12 4 FUME PIPES ANNUAL CLEANING Clean annually from soot with brushes The cleaning operation must be executed by a specialized stove repairer who wi...

Page 29: ...from the flue or leave the door slightly open humidity damages the ignition resistance over time 13 IN CASE OF ANOMALY 13 1 PROBLEM SOLVING Before of every Authorized Technician intervention the same...

Page 30: ...by a foreign object for example nails Clean the auger The auger geared motor is out of order Replace the geared motor Check if on the display there is an ACTIVE ALARM Have the stove checked The fire e...

Page 31: ...erature probe Replace the fume probe Faulty mother board Replace the mother board Ash remains along the stove Faulty or out of order door gaskets Replace the gaskets Not sealed fume pipes Contact an e...

Page 32: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...