Pag. 78
MIRIAM-NICE-DIANA-PRETTY-MARY
5.16.
REMOTE CONTROL (OPTIONAL)
The stove can be controlled by a remote control (fit a type N 12V battery).
Picture 14
Button 1
Increases the required temperature.
Button 2
Decreases the required temperature.
Button 5
Decreases the power level from 1 to 5.
Button 6
Increases the power level from 1 to 5.
Buttons
1 and 6
Held down simultaneously ignite or turn
off the stove.
6.
SAFETY DEVICES
6.1.
FOREWORD
The purpose of the safety devices is to prevent and eliminate risks of harm to persons, animals or things.
It is prohibited to tamper with them and if they are repaired by unauthorized persons the warranty and
manufacturer’s liability are annulled.
6.2.
PRESSURE SWITCH ALARM
A pressure switch is connected to the boiler to control draught. When the display shows “AlAr dEp” the
pressure switch cuts out electricity to the auger and starts the turning off process. The circuit board
keeps the fumes extractor on for 15 minutes for the stove to cool. Reset the error pushing ON/OFF
button. Check the type of fault, as shown on
page 85
. After removing the cause of the fault, clean the
burn pot and start the stove with the ON/OFF button.
6.3.
FUMES THERMOCOUPLE ALARM
The stovepipe is connected to a probe that constantly monitors working temperature. When the display
shows “AlAr Sond” it means that the probe is damaged or disconnected. The electronic circuit board cuts
out electricity to the auger and starts the turning off process. The circuit board keeps the fumes extractor
on for 15 minutes for the stove to cool. Reset the error pushing ON/OFF button. Check the type of fault,
as shown on
page 84
. After removing the cause of the fault, clean the burn pot and start the stove with
the ON/OFF button.
6.4.
FAILED IGNITION ALARM
The fumes thermocouple also controls failed ignition and cuts in if the temperature is too low for
ignition, when the display shows “AlAr no FirE”. The circuit board keeps the fumes extractor on for 15
minutes for the stove to cool. Reset the error pushing ON/OFF button. Check the cause of the fault, as
shown on
page 83
. After removing the cause of the fault, clean the burn pot and start the stove with the
ON/OFF button.
Summary of Contents for mary
Page 2: ...Pag 2 MIRIAM NICE DIANA PRETTY MARY Figura 1 Figura 2 ...
Page 33: ...MIRIAM NICE DIANA PRETTY MARY Pag 33 Image 1 Image 2 ...
Page 62: ...Pag 62 MIRIAM NICE DIANA PRETTY MARY Picture 1 Picture 2 ...
Page 91: ...MIRIAM NICE DIANA PRETTY MARY Pag 91 NOTES ...
Page 92: ...Pag 92 MIRIAM NICE DIANA PRETTY MARY NOTES ...