THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM
AND BECOME PROFICIENT IN ITS OPERATION. ALL USERS OF YOUR SECURITY
SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN
THIS BOOKLET. FAILURE TO DO SO COULD RESULT IN THE SECURITY SYSTEM NOT
WORKING PROPERLY.  THIS BOOKLET SHOULD BE KEPT IN AN ACCESSIBLE
LOCATION FOR THE LIFE OF THE SECURITY SYSTEM. IF YOU DO NOT UNDERSTAND
ANY PART OF THIS MANUAL YOU SHOULD NOTIFY YOUR INSTALLING COMPANY AND
ASK FOR THAT SECTION OF THE MANUAL TO BE EXPLAINED FULLY.

The SECURITY CONTROL CENTER is turned on (ARMED) and off (DISARMED) by entering
a 4 digit code into the Keypad Control,, which is similar to a telephone keypad.  The Keypad
Control includes 10 indicator lights and a built-in electronic sounder.  These provide specific
information relating to the status of the security system which is described in this booklet.
Understanding what the lights and sounds mean will help you easily operate your system.

SO REMEMBER, READ THE ENTIRE MANUAL, AND IF POSSIBLE, PRACTICE ON THE
KEYPAD CONTROL WHILE YOUR PROFESSIONAL INSTALLER IS AT YOUR SITE. IF
YOU HAVE ANY QUESTIONS, ASK YOUR INSTALLING COMPANY.

PLEASE KEEP IN MIND THAT THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS
SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS:

  1. The quantity, quality, and placement of security devices  attached to this system.
  
  2.  The knowledge you have of the security system and how that knowledge is utilized in a

weekly test of the complete system.

YOU SHOULD BE AWARE OF THE FOLLOWING FACTS AND USE THEM WHEN
PREPARING A SAFETY/SECURITY PLAN FOR YOUR HOME/BUSINESS.

  1.  Your security system is an electronic device and is subject to failure or malfunction. Do

not rely on it as your single source of security.

  
  2.  Your system should be tested weekly.
  
  3.  Your system will not work without power.
  
  4.  Warning devices will need to be loud enough, wired correctly, and properly placed to 

provide notification of an alarm event.

  
  5.  Smoke and heat detectors may not detect heat and smoke in all situations.
  
  6.  Use qualified security professionals to select, install, and  maintain your security system.
  
  7.

It may be possible to arm the security system without the backup battery connected. Your
periodic test should be done with A.C. Power removed to verify the battery is connected
and adequately charged.

  
  8.  Care should be taken to plug in and properly restrain the A.C. Transformer after testing.

PLEASE READ THIS ENTIRE BOOKLET CAREFULLY BEFORE OPERATING YOUR
SECURITY CONTROL SYSTEM. IF YOU DO NOT UNDERSTAND ANY PORTION OF THIS
MANUAL, OR IF YOU HAVE ANY QUESTIONS ABOUT YOUR SYSTEM, CONTACT THE
INSTALLING COMPANY LISTED ON PAGE 1 OF THIS BOOKLET.

www.ealarm.com.my

Summary of Contents for 8600

Page 1: ...LATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS AND USE THEM WHEN PREPARING A SAFETY SECURITY PLAN FOR YOUR HOME BUSINESS 1 Your security system is an electron...

Page 2: ...ssed NOTE If the exit door is open when the exit delay expires the siren will sound and the entry delay will begin If a valid code is not entered prior to the expiration of the entry delay an alarm report will be transmitted to the monitoring station if the system is monitored Entering a valid code during the entry delay will disarm the system silence the siren and keep an alarm report from being ...

Page 3: ...installing company may have programmed the INSTANT option to occur in conjunction with the AUTOMATIC BYPASS feature In this case the INSTANT light and the bypassed ZONE lights will become illuminated at the end of the exit delay If this occurs you still have the ability to turn the INSTANT feature off and or on by pressing the U key GROUP BYPASS OPTION K If checked the GROUP BYPASS option has been...

Page 4: ...ond to the Panic Hold Up activation KEYPAD ACTIVATED FIRE ALARM If checked this feature has been selected by your installing company If so you can activate the Fire alarm by pressing the one 1 and three 3 keys at the same time for one second If your system is connected to a monitoring center an emergency report could be sent to that center These keys should only be pressed in an emergency situatio...

Page 5: ...de 1 and up to 13 auxiliary codes All codes must have 4 digits These Auxiliary codes are individually numbered from 2 to 14 NOTE If your system is programmed for a DURESS code mentioned above user code 7 will not be available If Auxiliary codes are desired they must be programmed individually Codes 2 thru 7 can be changed by the procedures described below while codes 8 thru 14 can only be changed ...

Page 6: ... the system standby battery is low ZONES YELLOW Flashing means unsecured Steady means bypassed Off means secure KEYPAD CONTROL TONES BEEPS A sounder is built into the keypad and may sound for any of the following reasons Beeps for all keypresses Sounds a continuous tone during the Entry delay time Pulses when a day zone is violated while the system is disarmed Pulses when a FIRE zone has a trouble...

Page 7: ...one light should blink Walk into all areas protected by motion detection devices while someone observes the Keypad Control The appropriate yellow zone light should blink for each sensor tested If your system has a FIRE Zone the Smoke or Heat detectors should be tested at least monthly If your Security System is monitored by a Central Monitoring Station always call before to let them know that you ...

Reviews: