1
1
CAUTION
Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
must be provided.
IMPORTANT
Read these instructions carefully so as to familiarise yourself with the appliance before fitting the appliance to a gas cylinder.
Retain these instructions for future reference.
GB
1. General
• This appliance complies with BS EN 498: 2012, EN 484:1997 and SANS 1539: 2012
• This appliance must only be used with an approved hose and regulator. (A 2.8kPa hose and regulator supplied only in South Africa)
• The gas cylinder is to be used only in the upright position.
• Use of pot with minimum size of 150mm and maximum size of 300mm.
• Gas appliances require ventilation for efficient performance and to ensure the safety of users and other persons in close proximity.
•
Warning:
Accessible parts may be very hot. Keep young children away.
• After use, turn off the gas supply at the cylinder, and then at the control knobs.
•
Use outdoors only!
Country of use
DK, FI, NO, NL, SE,
AT, SI
BE, ES, FR, IE, IT, PT,
GB, CH
PL
AT, CH, DE
Appliance Catagories
I3B/P (30)
I3+ (28-30/37)
I3B/P (37)
I3B/P (50)
Allowable gases and
operating pressure
Butane @ 28-30mBar
Propane @ 28-30mBar
Butane/Propane mixtures
@ 28-30mBar
(SA - LPG @ 2,8kPa)
Butane @ 28-30mBar
Propane @ 37mBar
Butane @ 37mBar
Propane @ 37mBar
Butane/Propane mixtures
@ 37mBar
Butane @ 50mBar
Propane @ 50mBar
Butane/Propane mixtures
@ 50mBar
Main 3 Burner BBQ unit
(98250-31, 98250-33)
Jet number
0.91
0.91
0.91
0.80
Nominal usuage
Butane - 255 g/h
per burner
Butane - 255 g/h
per burner
Butane - 277 g/h
per burner
Butane - 255 g/h
per burner
Gross nom. heat input
3.5 kW per burner
(10.5 kW in total)
3.5 kW per burner
(10.5 kW in total)
3.8 kW per burner
(11.4 kW in total)
3.5 kW per burner
(10.5 kW in total)
Gas supply sources:
a)
A refillable gas container not exceeding 11kg and complying with local regulation in force.
Main 4 Burner BBQ unit
(98251-41, 98251-43)
Jet number
0.91
0.91
0.91
0.80
Nominal usuage
Butane - 255 g/h
per burner
Butane - 255 g/h
per burner
Butane - 277 g/h
per burner
Butane - 255 g/h
per burner
Gross nom. heat input
3.5 kW per burner
(14 kW in total)
3.5 kW per burner
(14 kW in total)
3.8 kW per burner
(15.2 kW in total)
3.5 kW per burner
(14 kW in total)
Side Burner (98250-33, 98251-43)
Jet number
0.73
0.64
Nominal usuage
Butane - 160 g/h
Butane - 160 g/h
Butane - 182 g/h
Butane - 160 g/h
Gross nom. heat input
2.2 kW per burner
2.2 kW per burner
2.5 kW per burner
2.2 kW per burner
1) For gas categories I3B/P(30), I3B/P(50) & I3+
Entertainer 3B with side tables, models 98250-31, total nominal heat input 10.5kW @ 765g/h.
Entertainer 4B with side tables, models 98251-41, total nominal heat input 14kW @ 1020g/h.
Entertainer 3B with side table & side burner, models 98250-33, total nominal heat input 12.7kW @ 925g/h.
Entertainer 4B with side table & side burner, models 98251-43 total nominal heat input 16.2kW @ 1180g/h.
2) For gas categories I3B/P(37)
Entertainer 3B with side tables, models 98250-31, total nominal heat input 11.4kW @ 831g/h.
Entertainer 4B with side tables, models 98251-41, total nominal heat input 15.2kW @ 1108g/h.
Entertainer 3B with side table & side burner, models 98250-33, total nominal heat input 13.9kW @ 1013g/h.
Entertainer 4B with side table & side burner, models 98251-43 total nominal heat input 17.7kW @ 1290g/h.
503-0604 LEV7 (98250-31, 98250-33, 98251-43) Cadac Entertainer 3 & 4 - User Manual (EU & SA).indd 1