Revision 1 2017
CDC seven
25
Power supplies
The CDC PSU 4800 is a 2U unit supplying all DC voltages required by the control
surface via a single multiway cable terminating in a 12-pin Jaeger connector.
There are three DC power rails: +17 V, -17 V and +12.5 V.
1
3
4
2
5
6
7
Front panel
1. POWER – the on/off switch is the mains disconnect device for the console.
2. Mains fuses – one each in the line and neutral of the AC input. See table
below for ratings.
3. DC output LEDs – one red LED for each DC output.
4. Air intakes – do not obstruct.
Rear panel
5. MAINS INPUT - Neutrik powerCON TRUE1 male connector for AC mains.
Max rating 16 A. A female powerCON connector is also provided; this is
paralleled to the input connector. It may be used to link AC mains to a
second PSU or other equipment. Total AC current consumption when
linking units in this way must not exceed the input connector’s current
rating of 16 A.
6. POWER OUTPUT – locking 12-pin Jaeger connector. Connect to the
control surface with the cable supplied.
7. Air exhaust vents – do not obstruct.
The PSU is of the “Universal” type, and will operate on all mains voltages from 90
to 250 V, 50/60 Hz. The PSU is rated at 1200 W AC.
Fuse data
Rating
Type
230 V
3.15 A
20 mm T3.15AL 250V
115 V
6.3 A
20 mm T6AL 250V