background image

2

2

3. Assembly Instructions

PLEASE NOTE: 

Please ensure all protective packaging and plastic are removed from the appliance before use.

This appliance may only be used with an approved hose and regulator (hose and regulator supplied with this unit in South Africa)

Connect the regulator to a CADAC 3kg, 5kg or 7kg LPG cylinder prior to use.

If you wish to use the appliance with a 9kg cylinder, please ensure that you have purchased the correct hose and regulator suitable for a 

9kg cylinder.

The hose length should be no less than 600 mm and shall not exceed 1.2 m and replace when the hose is damaged or shows signs of brittleness 

or cracks.

Do not twist or pinch the hose. Ensure that it is routed away from the Stove Body so as to prevent deterioration / damage to the hose 

caused by heat.

Ensure that the appliance valves are in the off position by turning the knobs fully clockwise to the stop.

Open the gas valve on the cylinder and test for any leaks.

Check all gas connections for any signs of gas leaks.

Your appliance is now ready to be used.

I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37),

 

Appliance categories: (DK, FI, NO, NL, SE, AT, DE, BE, ES, FR, IE, IT, PT, GB, CH)

Push an approved hose onto the valve tailpiece until it is properly seated. On the other end, attach a suitable low pressure regulator.

I3B/P(30) : 30mbar Butane confi gurations regulator or 30mbar Propane confi gurations regulator.

I3B/P(37) : 37mbar Butane confi gurations regulator or 37mbar Propane confi gurations regulator.

I3+(28-30/37) : 30mbar Butane confi gurations regulator or 37mbar Propane confi gurations regulator.

Again making sure that the hose is properly seated. The type of hose used shall comply with the relevant EN standard and locate 

requirement. In South Africa the regulator used must comply with SANS 1237.

I 3B/P (50) Appliance category: (AT, DE)

I3B/P(50) : 50mbar Butane confi gurations regulator or 50mbar Propane confi gurations regulator or 50mbar butane/propane mixture 

confi gurations regulator. 

Screw a hose with the correct threaded fi ttings on each end, onto the left hand 1/4” BSP thread of the valve. Attache a suitable 50mbar 

low-pressure regulator on the end of the hose. The hose assembly used must comply with DIN 4815 part 2 or equivalent.

Country of Use

BE, CH, CY, CZ, ES, FR, GB, GR, 

IE, IT, LT, LU, LV, PT, SK & SI 

PL

BE, CY, DK, EE, 

FR, FI, HU, IT, LT, 

NL, NO, SE, SI, 

SK, RO, HR, TR, 

BG, IS,LU, MT

& ZA

AT, CH, DE & SK

Appliance Catagories

I

3+(28-30/37)

I

3B/P (37)

I

3B/P (30)

I

3B/P (50)

Allowable gasses

Butane-G30

Propane-G31

Butane-G30, Propane-G31 or their mixture

Gas Pressure

28-30mBar

37mBar

37mBar

28-30mBar

(2.8kPa for South 

Africa)

50mBar

Jet Number

0.71

0.71

0.71

0.62

Nominal Usage

Butane - 145.5 g/h

per burner 

(145.5g/h x 2 = 291g/h in total)

Butane - 160 g/h

per burner

(160g/h x 2 = 320g/h 

in total)

Butane - 145.5g/h

per burner

(145.5g/h x 2 = 

291g/h in total)

Butane - 145.5g/h

per burner

(145.5g/h x 2 = 

291g/h in total)

Gross nom. heat input

2kW per burner

(2kW x 2 = 4kW in total)

2.2kW per burner

(2.2kW x 2 = 4.4kW 

in total)

2kW per burner

(2kW x 2 = 4kW 

in total)

2kW per burner

(2kW x 2 = 4kW 

in total)

Country Name and Abbreviations

AE = United Arab Emirates

AL = Albania

AT = Austria

BE = Belgium

CH = Switzerland

CZ = Czech Republic

DE = Germany

DK = Denmark

ES = Spain

FI = Finland

FR = France

GB = United Kingdom

GR = Greece

HR = Croatia

IT = Italy

JP = Japan

KR = Korea

NL = Netherlands

NO = Norway

PL = Poland

PT = Portugal

RO = Romania

RU = Russia

RS = Serbia

SI = Slovenia

SK = Slovakia

SE = Sweden

TR = Turkey

ZA = South Africa

GB

Summary of Contents for 202P1

Page 1: ...2 COOK 2 PRO 503 0543 LEV17 MODEL No 202P1 202P0 28mBar 50mBar USER INSTRUCTIONS LIVE THE BRAAI LIFE NOTE PRODUCT MAY VARY FROM ILLUSTRATIONS GB DE DK ES FR IT NL NO PL SE SI 202P1 202P0 ...

Page 2: ...ials Minimum safe distances above the appliance 1 2 m at the rear and sides 600mm Do not use an appliance that is leaking damaged or which does not operate properly Ensure that the gas cylinder is fitted or changed in a well ventilated location preferably outdoors away from any sources of ignition such as naked flames and away from other people Keep gas cylinders away from heat and flame Do not pl...

Page 3: ...is properly seated The type of hose used shall comply with the relevant EN standard and locate requirement In South Africa the regulator used must comply with SANS 1237 I 3B P 50 Appliance category AT DE I3B P 50 50mbar Butane configurations regulator or 50mbar Propane configurations regulator or 50mbar butane propane mixture configurations regulator Screw a hose with the correct threaded fittings...

Page 4: ...3 3 Product Code 202P1 20 Ribbed Grill Plate Lid Burner Piezo Control Knob Flat Grill Plate Pot Stand GB Product Code 202P0 10 Lid Pot Stand Burner Control Knob ...

Page 5: ...orrect amount of gas Should the hole in the Jet become blocked this may result in a small flame or no flame at all Do not attempt to clean the jet with a pin or other such device as this may damage the orifice which could make the appliance unsafe Replacing a blocked jet Ensure that the cylinder valve is closed then disconnect the appliance from the gas cylinder Remove the Potstand cooking surface...

Page 6: ... in a detergent solution To clean the stove body simply wipe with a damp cloth using a little detergent if necessary DO NOT IMMERSE IN WATER as this will allow water to get into the burner tube causing the appliance to malfunction Do not use abrasive cleaners or scourers as this will cause permanent damage to the surface To avoid ignition failure keep the burners clean Use a brush to clean the bur...

Page 7: ...mited Warranty does not cover any failures or operating difficulties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure to perform normal and routine maintenance including but not limited to damage caused by insects within the burner tubes as set out in this owner s manual Deterioration or damage due to severe weathe...

Reviews: