background image

 

 22

 

Table 12: Part lists with variable speed motor (ECM) 

Item

Part

Description

Comments

1

B03690

HEAT EXCHANGER ASSEMBLY

Heat exchanger only

2

J06L002

SEAL STRIP DIA 1/8" DIA X 25'

3

B03696

FLOOR ASSEMBLY

4

B03709

WIRE CHANNEL, INT

5

B03695-01

LOWER BLOWER DIVIDER ASSEMBLY

Panel, 3 gaskets and baffle included

6

B03719

CENTER BLOWER DIVIDER

7

B03335-02

ELECTRICAL KIT, BVSO INT

8

B03708

SIDE BAFFLE

9

B03694-02

LEFT SIDE PANEL ASSEMBLY

Panel, insulation and baffle included

10

B03714-02

LEFT SIDE PANEL INSULATION

11

B03711-02

LEFT ANGLE FILTER RACK

12

B03710

SIDE FILTER RACK

13

Z04F004

PAPER FILTER 20 X 20 X 1

14

B03697

BLOWER DOOR ASSEMBLY

Door, handle and labels included

15

Z99F050

HANDLE, RECESSED BLACK

16

B03577

REAR FILTER DOOR ASSEMBLY

17

F07O001

HEX FLANGE NUT 3/8-16NC LAITON

18

B01697

FLUE OUTLET FLANGE, 5" DIA.

19

B01214

GASKET, SMOKE PIPE COVER

20

B03693

TOP REAR PANEL ASSEMBLY

Panel and label included

21

B03718

REMPLACEMENT SOUND TRAP ASSEMBLY

2 sections included

22

B03712

OUTLET PROTECTOR

23

B03705

TOP DIVIDER

24

B03694-01

RIGHT SIDE PANEL ASSEMBLY

Panel, insulation and baffle included

25

B03714-01

RIGHT SIDE PANEL INSULATION

26

B03711-01

RIGHT ANGLE FILTER RACK

27

B03553

ELECTRICAL BOX SPACER

28

B03534

ELECTRICAL BOX

29

R02R003

HIGH LIMIT L195-30F, 1.75 in.

30

B03550

ELECTRICAL BOX COVER

Panel only

31

B03118-01

ELECTRICAL KIT, BVSO EXT

32

F06F015

ZINC WASHER 1 7/16"

33

Z99F061

SIGHT GLASS FOR HEAT EXCHANGER

34

Z06G001

BLOCKED VENT SHUT-OFF BVSO-225

35

B03587

CLEAN OUT ASSEMBLY

Item #37 included

36

B03574-01

PROTECTION COVER ASSEMBLY

Cover and labels included

37

B03428

GASKET, SMOKE OUTLET 

38

F07F011

HEX NUT 3/8-16NC ZINC

39

B03567

BAFFLE

One baffle uncluded

40

B03596

BURNER WIRE CHANEL

41

B03554

WIRE CHANEL

42

L04I010

STRAIN REL. BUSHING 

43

B03573

FRONT PANEL ASSEMBLY

Panel and insulation uncluded

44

B03590

FRONT PANEL INSULATION

45

B03555

THERMO DISK PROTECTOR

46

B03465

ELECTRICAL KIT (BOARD)                    

47

R99G003

ELECTRONIC BOARD 1168

48

L01F009

TRANSFORMER  120-24Volts, 40VA

49

B03243-01

ELECTRIC BLOWER KIT                     

50

B03242-01

ELECTRONIC BLOWER KIT

51

B03812-02

MOTOR 3/4 HP ECM

52

"N/A"

MOTOR MODULE 1/2 ECM

53

B01889

MOTOR MOUNT ASSEMBLY

Band, legs, nut & bolts included

54

B03713

BLOWER SUPPORT

55

B03720-06

BLOWER 120-9T DD 0.5 PP

Housing, wheel and label included

56

B03717-02

REPLACEMENT BLOWER ASSEMBLY

Blower and motor included

57

L01G009

CONTROL CARD FUSE - 3 AMPS

VENT TERMINAL KIT 4''

For sealed combustion

4" INSULATED FLEX VENT 10ft

For sealed combustion

4" INSULATED FLEX VENT 15ft

For sealed combustion

4" INSULATED FLEX VENT 20ft

For sealed combustion 

BECKETT AFG BURNER (0.60-60W NOZZLE)

BECKETT NX BURNER (0.60-60W NOZZLE)

RIELLO 40-F5 BURNER (0.60-70A NOZZLE)

RIELLO 40-BF5 BURNER (0.60-70A NOZZLE)

For sealed combustion

N01F052

KLABR0401RLO

N01J052

KLABR0201BEC

ACCESSORIES

N01F051

KLABR0301RLO

IFV-415

IFV-420

IFV-098-20

KLAFV0201DET

N01J055

IFV-410

IFV-098-10

KLAFV0101DET

VTK-54

VTK-098

KLAVT0101DET

 

B50094F 

 

 

Summary of Contents for OBL112

Page 1: ... Keep this booklet of information for future reference SERVICER Use the information in this booklet to service the appliance and affix the booklet adjacent to the appliance after servicing ama B140 4 UL727 Copyright 2011 CAC BDP D 7310 W Morris St D Indianapolis IN 46231 Printed in U S A Edition Date 03 13 Manufacturer reserves the right to change at any time specifications and designs without not...

Page 2: ... speed motor 5 Figure 3 Thermostat wiring heating and air conditioning with ECM variable speed motor 5 Figure 4 Thermostat wiring heating and air conditioning heat pump with ECM variable speed motor 5 Figure 5 Supply air adjustments start stop delays board 1158 8 Figure 6 Furnace dimensions 16 Figure 7 Wiring diagram 4 speed motor PSC 17 Figure 8 Wiring diagram variable speed motor ECM 18 Figure 9...

Page 3: ...quired information such as the model and serial numbers of the furnace WARNING Installations and repairs performed by unqualified persons can result in hazards to them and to others Installations must conform to local codes or in the absence of same to codes of the country having jurisdiction The information contained in this manual is intended for use by a qualified technician familiar with safet...

Page 4: ...led in an area where the ambient and return air temperatures are above 15 C 60 F In addition the furnace should be installed as closely as possible to the vent so that the connections are direct and kept to a minimum The heater should also be located close to the centre of the air distribution system 2 1 1 Installation in an enclosure The unit can be installed in an enclosure such as a closet Howe...

Page 5: ...rner comes However if anoth required use the manufacturer s recommended spray angle and type a shown in Table 7 and based on a pump pressure of 100 psi Always select nozzle sizes by working back from the desired flow rate at op marking 2 4 2 Air and Turbulator Settings Before starting the burner for the first tim and turbulator settings to those listed Table 7 Once the burner becomes operational f...

Page 6: ...tch will shut down the oil burner The device will then need to be re armed MANUALLY Refer to the detailed instructions and wiring diagrams supplied with the BVSO for the installation and wiring procedures The length of wires supplied with the unit is such that the safety device must be installed between the flue outlet of the appliance and the draft regulator as indicated in the instructions It is...

Page 7: ...for leaks Ensure that the tank is full of clean oil Use No 1 or No 2 Heating Oil ASTM D396 U S or in Canada use No 1 or No 2 Furnace Oil A manual shut off valve and an oil filter shall be installed in sequence from tank to burner Be sure that the oil line is clean before connecting to the burner The oil line should be protected to eliminate any possible damage Installations where the oil tank is b...

Page 8: ...itioning mode variable speed motor ECM SW2 COOL DIP Switch Positions 1 2 POSITION Output Tons OFF OFF A 4 0 ON OFF B 3 5 OFF ON C 3 0 ON ON D 2 5 Table 5 Supply air adjustments all modes variable speed motor ECM SW3 ADJ Adjustment DIP Switch Positions 1 2 POSITION CFM HTG increase or decrease CFM A C increase or decrease OFF OFF A 0 0 ON OFF B 10 10 OFF ON C 10 10 ON ON D N A 0 Table 6 Delay adjus...

Page 9: ...oses 2 The burner motor starts up to pre purge the combustion chamber for a period of 10 to 15 seconds During that time a spark is established on the electrodes 3 The solenoid valve opens and a flame is established Shortly after the electrodes cease to spark 4 Then the blower runs up to full speed The delay depends on the adjustments that were made on the electronic board which controls the blower...

Page 10: ...use of an oversize nozzle input or high pressure pump 3 3 6 Vent Temperature Test 1 After having adjusted the burner combustion insert a thermometer into the test hole in the breech pipe 2 The total vent temperature should be between 204 and 302 C 400 and 575 F If not check for improper air temperature rise pump pressure nozzle size or a badly sooted heat exchanger Also refer to section 2 5 for pr...

Page 11: ...ore each heating season to determine whether the cleaning or replacement of parts is necessary If a cleaning is necessary the following steps should be performed 1 Turn OFF all utilities upstream from the furnace 2 Disconnect the flue pipe 3 Remove the flue collar panel located at the rear of the furnace 4 Remove the clean out door located at the front of the furnace 5 Remove the heat exchanger ba...

Page 12: ...rvice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Ambient temperature F Chimney draft W C Overfire draft W C Test performed by ...

Page 13: ...AFUE From CSA B212 standard and Canadian regulation 87 4 86 5 87 4 86 5 AFUE From ASHRAE 103 standard and US regulation 87 2 86 5 87 2 86 5 Volts Hertz Phase Rated current Amps Minimum ampacity for wire sizing Amps Max fuse size Amps Control transformer VA External control power available Heating VA Cooling VA Heating blower speed at 0 25 W C SP MED LOW MED HIGH Heating blower speed at 0 50 W C SP...

Page 14: ...ime ShortRun On Delay CFM Level Time Off Delay CFM Level Time A 1 OFF 2 OFF 0 68 13 45 sec 19 60 sec 38 3 min B 1 ON 2 OFF 0 80 13 45 sec 19 30 sec 38 3 min C 1 OFF 2 ON All 13 45 sec 100 0 sec 100 2 min D 1 ON 2 ON All 13 90 sec 100 0 sec 100 2 min No adjustment required A C size PreRun On Delay CFM Level Time ShortRun On Delay CFM Level Time Off Delay CFM Level Time All NO DELAY NO DELAY 100 90 ...

Page 15: ...ESSUREWITH AIR FILTER Table 10 Minimum clearances from combustible material LOCATION CLEARANCES combustible materials RECOMMANDED ACCESS FORSERVICE FURNACE 2 54 cm 1 0 6 m 24 SUPPLY PLENUMWITHIN6 FEETOFFURNACE 2 54 cm 1 BACK ACCESS PANEL TOBLOWER 10 16 cm 4 0 6 m 24 FURNACEORPLENUM 5 08 cm 2 HORIZONTAL WARMAIRDUCTWITHIN 6 FEETOFFURNACE 5 08 cm 2 BOTTOM FURNACE COMBUSTIBLEFLOOR 0 cm 0 FLUEPIPE AROU...

Page 16: ...16 Figure 6 Furnace dimensions ...

Page 17: ...17 Figure 7 Wiring diagram 4 speed motor PSC ...

Page 18: ...18 Figure 8 Wiring diagram variable speed motor ECM ...

Page 19: ...19 Figure 9 Parts list with 4 speed motor PSC B50093B ...

Page 20: ... 16 33 Z99F061 SIGHT GLASS FOR HEAT EXCHANGER 34 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 35 B03587 CLEAN OUT ASSEMBLY Item 37 included 36 B03574 01 PROTECTION COVER ASSEMBLY cover and labels included 37 B03428 GASKET SMOKE OUTLET 38 F07F011 HEX NUT 3 8 16NC ZINC 39 B03567 BAFFLE One baffle uncluded 40 B03596 BURNER WIRE CHANEL 41 B03554 WIRE CHANEL 42 L04I010 STRAIN RELIEF BUSHING 43 B03573 FRONT P...

Page 21: ...21 Figure 10 Parts list with variable speed motor ECM B50094B ...

Page 22: ...015 ZINC WASHER 1 7 16 33 Z99F061 SIGHT GLASS FOR HEAT EXCHANGER 34 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 35 B03587 CLEAN OUT ASSEMBLY Item 37 included 36 B03574 01 PROTECTION COVER ASSEMBLY Cover and labels included 37 B03428 GASKET SMOKE OUTLET 38 F07F011 HEX NUT 3 8 16NC ZINC 39 B03567 BAFFLE One baffle uncluded 40 B03596 BURNER WIRE CHANEL 41 B03554 WIRE CHANEL 42 L04I010 STRAIN REL BUSHING 4...

Page 23: ...erver ce manuel d information pour références ultérieures TECHNICIEN DE SERVICE Utiliser l information contenue dans ce manuel afin d effectuer l entretien de l appareil Garder ce manual près de l unité pour références ultérieures ama B140 4 UL727 Copyright 2011 CAC BDP D 7310 W Morris St D Indianapolis IN 46231 Printed in Canada Edition Date 03 13 Le manufacturier se réserve le droit de modifier ...

Page 24: ...nité avec moteur 4 vitesses 5 Figure 3 Branchement du thermostat chauffage et climatisation unité avec moteur ECM 5 Figure 4 Branchement du thermostat chauffage et climatisation thermopompe unité avec moteur ECM 5 Figure 5 Délais de départ et d arrêt du ventilateur carte 1158 9 Figure 6 Dimensions de la fournaise 18 Figure 7 Diagramme électrique moteur 4 vitesses PSC 19 Figure 8 Diagramme électriq...

Page 25: ...filtre à air comment le changer vérifier mensuellement et nettoyer ou changer si nécessaire g Avant d appeler pour le service ayez en main la page de la fiche technique section 5 de ce manuel pour le numéro du modèle et le numéro de série de la fournaise MISE EN GARDE L installation ou les réparations par du personnel non qualifié peuvent entraîner des risques pour vous et à autrui L installation ...

Page 26: ...ule l édition la plus récente des codes doit être utilisée 2 1 EMPLACEMENT MISE EN GARDE Risque d incendie ou d explosion L appareil doit être installé au niveau Ne jamais installer avec une inclinaison vers l avant Ne pas ranger ou utiliser d essence ou toutes autres substances inflammables à proximité de l appareil Ne pas se conformer à ces instructions pourrait entraîner la mort ou des dommages...

Page 27: ... remplacez des fils d origine de l appareil de chauffage central utilisez seulement du fil de cuivre résistant à la même température que les fils d origine 2 3 INSTALLATION DU THERMOSTAT L installation d un thermostat de contrôle de la température de l espace à chauffer est obligatoire Suivre les instructions d installation incluses avec le thermostat Consulter aussi les diagrammes électriques fou...

Page 28: ...trôle du brûleur pour plus de détail concernant l ajustement du délai post purge 2 5 ÉVACUATION MISE EN GARDE Risque d empoisonnement par monoxyde de carbone Lire et suivre toutes les instructions contenues dans cette section Ne jamais installer un volet manuel sur le tuyau d évacuation Cependant un volet motorisé à fonctionnement automatique approuvé par une agence certifiée peut être installé si...

Page 29: ...e refroidissement Si le fonctionnement n est pas conforme APPELER UN TECHNICIEN QUALIFIÉ 2 7 APPROVISIONNEMENT EN AIR DE COMBUSTION ET VENTILATION MISE EN GARDE Risque d empoisonnement par monoxyde de carbone Référer aux codes d installation des appareils au mazout ANSI NFPA 31 aux États Unis ou CSA B139 au Canada et aux codes locaux pour fournir l air de combustion et de ventilation Une quantité ...

Page 30: ...t de faire le raccordement au brûleur Le conduit de mazout doit être protégé pour éviter un dommage à celui ci Les installations ayant un réservoir de mazout situé sous le niveau du brûleur doivent utiliser une ligne de retour de mazout vers le réservoir avec une pompe appropriée une élévation de 2 4 m 8 et plus requièrent une pompe deux stages et une élévation de plus de 4 9 m 16 une pompe auxili...

Page 31: ... à vitesse variable de type ECM il faut vérifier que le débit d air est ajusté en fonction de la puissance de chauffage et de climatisation Les délais de départ et d arrêt du ventilateur en mode chauffage doivent aussi être ajustés en positionnant les interrupteurs DIP du contrôle électronique Consulter les tableaux suivants le tableau 8 des débits d air et le diagramme électrique de ce manuel pou...

Page 32: ...aleur Si une thermopompe est installée un thermostat bi énergie ou un autre contrôle est recommandé pour prévenir l opération simultanée de la fournaise et de la thermopompe Il prévient aussi la transition directe du mode de chauffage thermopompe au mode de chauffage au mazout Référer aux instructions du thermostat ou du contrôle pour un branchement adéquat 3 OPÉRATION 3 1 MISE EN MARCHE Avant de ...

Page 33: ...ité environ 5 minutes 3 Ajuster l air au brûleur pour avoir une lecture de fumée Bacharach entre 0 et 1 ou une trace 4 Faire le test de CO2 à la même localisation et prendre en note la lecture Exemple 13 8 de CO2 ou 2 5 d O2 5 Ajuster la quantité d air pour obtenir une lecture du CO2 de 1 5 de moins ou O2 de 2 de plus que la lecture correspondant à une lecture de fumée Bacharach de une trace Exemp...

Page 34: ...arrer le brûleur lorsqu il y a un excès de mazout accumulé des vapeurs de mazout ou que la chambre à combustion est très chaude 4 ENTRETIEN MISE EN GARDE Risque de décharge électrique Avant d effectuer des travaux d entretien FERMER l alimentation du combustible et l alimentation électrique Ne pas se conformer peut entraîner la mort des blessures et ou des dommages matériels Les services d entreti...

Page 35: ...urface de l interrupteur thermique Un interrupteur thermique endommagé doit être remplacé 6 Nettoyer et enlever toute accumulation de saleté ou obstruction de l intérieur du tube de transfert de chaleur 7 Remonter verrouiller et fixer le boîtier de commande à l aide des 2 vis qui avait été enlevées à l étape 4 8 Remettre en place le couvercle de l ensemble avec les vis enlevées à l étape 2 9 Remet...

Page 36: ...u technicien de service RÉSULTAT DU TEST DE MISE EN MARCHE Gicleur Pression lb po 2 Ajustements du brûleur Bande principale Bande fine Position de la tête CO2 Indice de fumée Bacharach Température des gaz à la sortie de l unité F Température ambiante F Tirage dans la cheminée C E Tirage ou pression au dessus du feu C E Examiné par 14 ...

Page 37: ... standard CSA B212 et des lois canadiennes 87 4 86 5 87 4 86 5 AFUE À partir du standard ASHRAE 103 et des lois américaines 87 2 86 5 87 2 86 5 Volts Hertz Phase Consommation Amp Amp minimum pour grosseur du fil Amp Fusible max Amp Contrôle du transformateur VA Courant disponible contrôles externes Chauffage VA Climatisation VA Vitesse du ventilateur à une pression statique de 0 25 W C PS MED LOW ...

Page 38: ...ai On Niveau PCM Temps Délai Off Niveau PCM Temps A 1 OFF 2 OFF 0 68 13 45 sec 19 60 sec 38 3 min B 1 ON 2 OFF 0 80 13 45 sec 19 30 sec 38 3 min C 1 OFF 2 ON All 13 45 sec 100 0 sec 100 2 min D 1 ON 2 ON All 13 90 sec 100 0 sec 100 2 min Pas d ajustement requis Capacité climatisation PreRun Délai On Niveau PCM Temps ShortRun Délai On Niveau PCM Temps Délai Off Niveau PCM Temps Tout Aucun delai Auc...

Page 39: ...inimum matériaux combustibles 17 EMPLACEMENT APPLICATION DÉGAGEMENTS matériaux combustibles ACCÈS RECOMMANDÉ POUR L ENTRETIEN FOURNAISE 2 54 cm 1 0 6 m 24 PLÉNUM D ALIMENTATION JUSQU À 1 8m 6 DE LAFOURNAISE 2 54 cm 1 ARRIÈRE PORTE D ACCÈS AU VENTILATEUR 10 16 cm 4 0 6 m 24 FOURNAISE OU PLÉNUM 5 08 cm 2 HORIZONTALE À LA CONDUITE PREMIERS 1 8m 6 5 08 cm 2 DESSOUS FOURNAISE PLANCHER COMBUSTIBLE 0 cm ...

Page 40: ...Figure 6 Dimensions de la fournaise 18 ...

Page 41: ...19 Figure 7 Diagramme électrique moteur 4 vitesses PSC ...

Page 42: ...20 Figure 8 Diagramme électrique moteur vitesse variable ECM ...

Page 43: ...Figure 9 Liste de pièces avec moteur 4 vitesses PSC 21 B50093B ...

Page 44: ...D POUR ECHANGEUR 34 Z06G001 DISPOSITIF D ARRET BVSO 225 35 B03587 ASS BRIDE DE NETTOYAGE Comprend item 37 36 B03574 01 ASS COUVERCLE DE PROTECTION Comprend couvercle et étiquette 37 B03428 GARNITURE SORTIE A FUMEE 38 F07F011 ECROU HEXAGONAL 3 8 16NC ZINC 39 B03567 DEFLECTEUR Comprend un seul déflecteur 40 B03596 CACHE FIL BRULEUR 41 B03554 CACHE FIL 42 L04I010 CONNECTEUR PRESSION 43 B03573 ASS PAN...

Page 45: ...23 Figure 9 Liste de pièces avec moteur vitesse variable ECM B50094B ...

Page 46: ...Z99F061 OEIL DE REGARD POUR ECHANGEUR 34 Z06G001 DISPOSITIF D ARRET BVSO 225 35 B03587 ASS BRIDE DE NETTOYAGE Comprend item 37 36 B03574 01 ASS COUVERCLE DE PROTECTION Comprend couvercle et étiquette 37 B03428 GARNITURE SORTIE A FUMEE 38 F07F011 ECROU HEXAGONAL 3 8 16NC ZINC 39 B03567 DEFLECTEUR Comprend un seul déflecteur 40 B03596 CACHE FIL BRULEUR 41 B03554 CACHE FIL 42 L04I010 CONNECTEUR PRESS...