Table 7: Technical specifications
112 LOWBOY SERIES
Firing rate (USGPH)*
0,68
0,80
0,68
0,80
Input (BTU/h)*
95 200
112 000
95 200
112 000
Maximum Heating capacity, (BTU/h)*
81 100
94 100
81 100
94 100
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c. - no wind)
Overfire pressure with direct vent (inch of w.c. - no wind)
BECKETT BURNER; MODEL AFG (Chimney)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)**
0.60 - 60W
0.65 - 60B
0.60 - 60W
0.65 - 60B
Pump pressure (PSIG)*
140
150
140
150
Head/Air setting
8/0
7/0 (Note 1)
8/0
7/0 (Note 1)
AFUE % (From CSA B212 standard and Canadian regulation)***
87,2%
86,4%
87,2% ‡
86,4% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
87,1%
86,3%
87,1% ‡
86,3% ‡
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)**
0.60 - 60W
0.65 - 60W
0.60 - 60W
0.65 - 60W
Pump pressure (PSIG)*
140
150
140
150
Head/Air setting
3,0
3,5
3,0
3,5
AFUE % (From CSA B212 standard and Canadian regulation)***
88,1%
87,0%
88,1% ‡
87,0% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
87,0%
85,9%
87,0% ‡
85,9% ‡
RIELLO BURNER; MODEL 40-F3 (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)**
0.60 - 70A
0.70 - 70A
0.60 - 70A
0.70 - 70A
Pump pressure (PSIG)*
130
130
130
130
Combustion air adjustment (turbulator/damper)
1 / 2.6
2 / 3.1
1 / 2.6
2 / 3.1
AFUE % (From CSA B212 standard and Canadian regulation)***
87,6%
87,4%
87,6% ‡
87,4% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
86,6%
86,1%
86,6% ‡
86,1% ‡
RIELLO BURNER; MODEL 40-BF5 (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)**
0.60 - 70A
0.70 - 70A
0.60 - 70A
0.70 - 70A
Pump pressure (PSIG)*
130
130
130
130
Combustion air adjustment (turbulator/damper)
0 / 2.75
0 / 3.25
0 / 2.75
0 / 3.25
AFUE % (From CSA B212 standard and Canadian regulation)***
87,4%
86,5%
87,4% ‡
86,5% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
87,2%
86,5%
87,2% ‡
86,5% ‡
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer (VA)
External control power available Heating (VA)
Cooling (VA)
Heating blower speed at 0.25" W.C. SP
MED-LOW
MED-HIGH
Heating blower speed at 0.50" W.C. SP
MED-LOW
MED-HIGH
Motor (HP) / number of speeds
Blower size (diam. x width)
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size and quantity
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5" W.C. SP
Note 1 :
Without low firing baffle #5880.
* INPUT & OUTPUT ADJUSTMENT
- Pump pressure can be adjusted to maintain proper firing rate.
- Increase pump pressure if flue gases temperature is under 400°F.
- Adjust the total flue gas temperature between 400°F and 575°F (330°F and 505°F net approximately)
** Default Installed Nozzle in bold characters.
*** AFUE values established after minimum 20 hours of operation.
195 Lbs / 89 Kg
19 3/4'' x 19 3/4''
19 3/4'' x 19 3/4''
19 3/4'' x 19 3/4''
20'' x 20'' x 1" (or 2'')
16'' x 20'' x 1'' (quantity = 2)
20'' x 20'' x 1" (or 2'')
16'' x 20'' x 1'' (quantity = 2)
195 Lbs / 89 Kg
30
30
BLOWER DATA
See the ECM air flow table
40
40
40
40
15,2
14,7
20
15
BF5
BF5
2 3/4''
2 3/4''
F3 WITH AIR INLET DAMPER
F3 WITH AIR INLET DAMPER
2 3/4''
2 3/4''
1 3/4''
1 3/4''
6 - Slot LQ head
6 - Slot LQ head
2 - Slot L2 Head
2 - Slot L2 Head
NX56LQ
NX56LQ
AFG70MQSS
AFG70MQSS
1 3/4''
1 3/4''
+0.03 à +0.15
+0.03 à +0.15
+0.05 à +0.17
+0.05 à +0.17
-0.06 to -0.025
-0.06 to -0.025
-0.035 to +0.025
-0.035 to +0.025
UNITS WITH 1/2 HP 4-SPD MOTOR
UNITS WITH 3/4 HP ECM MOTOR
RATING AND PERFORMANCE
55° - 75°Degr. F
60° - 72°Degr. F
ELECTRICAL SYSTEM
115 - 60 - 1
115 - 60 - 1
12,6
12,2
4,0
4,0
3/4 HP / ECM (with power choke)
12'' x 9'' (tight housing)
12'' x 9'' (tight housing)
GENERAL INFORMATION
1/2 HP / 4 speeds
21'' x 48'' x 33''
21'' x 48'' x 33''
19 3/4'' x 19 3/4''
‡=
Summary of Contents for OBL112
Page 16: ...16 Figure 6 Furnace dimensions ...
Page 17: ...17 Figure 7 Wiring diagram 4 speed motor PSC ...
Page 18: ...18 Figure 8 Wiring diagram variable speed motor ECM ...
Page 19: ...19 Figure 9 Parts list with 4 speed motor PSC B50093B ...
Page 21: ...21 Figure 10 Parts list with variable speed motor ECM B50094B ...
Page 40: ...Figure 6 Dimensions de la fournaise 18 ...
Page 41: ...19 Figure 7 Diagramme électrique moteur 4 vitesses PSC ...
Page 42: ...20 Figure 8 Diagramme électrique moteur vitesse variable ECM ...
Page 43: ...Figure 9 Liste de pièces avec moteur 4 vitesses PSC 21 B50093B ...
Page 45: ...23 Figure 9 Liste de pièces avec moteur vitesse variable ECM B50094B ...