KSACN0101CAC

KSACN0101AAA

Owner’s Manual

Wired Remote Controller

Ductless Split Systems

SAFETY CONSIDERATIONS

Installing, starting up, and servicing air- conditioning equipment
can be hazardous due to system pressures, electrical components,

and equipment location (roofs, elevated structures, etc.).
Only trained, qualified installers and service mechanics should

install, start- up, and service this equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning coils. All other operations should be performed

by trained service personnel.
When working on the equipment, observe precautions in the

literature and on tags, stickers, and labels attached to the
equipment.
Follow all safety codes. Wear safety glasses and work gloves.

Keep a quenching cloth and fire extinguisher nearby when
brazing. Use care in handling, rigging, and setting bulky

equipment.
Read these instructions thoroughly and follow all warnings or

cautions included in literature and attached to the unit. Consult

local building codes and National Electrical Code (NEC) for
special requirements. Recognize safety information. This is the
safety- alert symbol

!

!

. When you see this symbol on the unit and

in instructions or manuals, be alert to the potential for personal
injury. Understand these signal words: DANGER, WARNING,

and CAUTION.

These words are used with the safety- alert

symbol. DANGER identifies the most serious hazards which

will

result in severe personal injury or death. WARNING signifies

hazards which

could

result in personal injury or death. CAUTION

is used to identify unsafe practices which

may

result in minor

personal injury or product and property damage. NOTE is used to
highlight suggestions which

will

result in enhanced installation,

reliability, or operation.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or

death.
Before beginning any modification or installation of this kit, be

sure the main electrical disconnect is in the OFF position.

Ensure power is disconnected to the fan coil unit. On some

systems both the fan coil and the outdoor unit may be on the

same disconnect. Tag the disconnect switch with a suitable

warning label. There may be more than one disconnect.

!

WARNING

EQUIPMENT DAMAGE HAZARD

Failure to follow this warning may result in equipment

damage.
Do not install wired controller in an area subjected to excessive

steam, oil or sulfide gas. Doing so may cause the controller to

deform and/or fail.

!

CAUTION

Kit Contents:

Confirm that all the following parts are included.

No.

Description

Qty

Remarks

1

Wired Remote Controller

1

n/a

2

Installation and owner’s

manual

1

n/a

3

Screws

3

M4X20 (for mount-

ing on the wall)

4

Wall plugs

3

For wall mounting

5

Screws

2

M4X25 (for mount-

ing on the wall)

6

Plastic screw bars

2

For fixing on the

switch box

7

The connective wires group

1

24AWG

Field Supplied Components:

Prepare the following on site.

Description

Qty

Type

Remarks

Switch Box

1

n/a

n/a

Wiring Tube

(insulating sleeve and

tightening screw)

1

n/a

n/a

S

This manual contains installation procedures for the wire
controller only. Refer to the indoor unit Installation Manual for
connecting the Wire Controller and the Indoor Unit.

S

Install the wire joint (5p) to the appointed position of the electric
controlling box.

S

The wired controller circuit is a low voltage circuit. Never
connect it with a standard 220V/380V circuit or place it in the
same wiring tube as the circuit. The interval must be more than
11.8- 19.7in. (300~500mm).

S

The shield cable must be connected stable to the ground or the
transmission may fail.

S

Do not extend the shield cable by cutting. If necessary, use a
Terminal Connection Block to connect.

S

After finishing the connection, do not use a Meggar to perform
the installation check to the signal wire.