165
Monitoring the Network from the Console Statistics Menu
SmartStack STS16-20RM/STS16-20FRM Token Ring Switches, P/N: 9032957-01
802.5 Statistics Screen
To open this screen, do the following:
1. Starting from the main menu, select
Statistics
→
→
→
→
Port Statistics.
2. Enter a port number.
3. Select
802.5 Statistics
...
Line Errors
This counter is incremented when a frame or token is copied or repeated by a
station, the E bit is zero in the frame or token, and one of the following conditions
exists:
1. There is a non-data bit (J or K bit) between the SD and the ED of the frame or
token.
OR
2. There is an FCS error in the frame.
Burst Errors
This counter is incremented when a station detects the absence of transitions for
five half-bit timers (burst-five error).
AC Errors
Number of times a station received an Active Monitor Present (AMP) frame or a
Standby Monitor Present (SMP) frame in which both the address recognized (A) bit
and the frame copied (C) bit are set to 0, indicating that no station has recognized
Summary of Contents for SmartStack STS16-20FRM
Page 1: ...SmartStack STS16 20RM STS16 20FRM Token Ring Switches Installation and User Guide...
Page 2: ......
Page 14: ...xii Notice...
Page 54: ...40 SmartStack STS16 20RM STS16 20FRM Token Ring Switches P N 9032957 01 Switch Overview...
Page 78: ...64 SmartStack STS16 20RM STS16 20FRM Token Ring Switches P N 9032957 01 Installation...
Page 232: ...218 SmartStack STS16 20RM STS16 20FRM Token Ring Switches P N 9032957 01 Troubleshooting...
Page 240: ...226 SmartStack STS16 20RM STS16 20FRM Token Ring Switches P N 9032957 01 Abbreviations...
Page 258: ...index 8 SmartStack STS16 20RM STS16 20FRM Token Ring Switches P N 9032957 01 Index...
Page 259: ......
Page 260: ...710001810...