Chapter 4: Troubleshooting
4-4
ESXMIM/ESXMIM-F2 Installation Guide
Cannot contact
the ESXMIM from
in-band
management
Improperly
configured
Community
Names table
Refer to
ESXMIM/ESXMIM-F2
Local Management Guide for
Community Names table setup.
ESXMIM does
not have an IP
address
Refer to
ESXMIM/ESXMIM-F2
Local Management Guide for IP
address Setup Screen information.
No link to device
Check link to device for validity and
proper functioning of all
intermediary devices.
User Parameters
(IP address,
Device and
Module Name,
etc.) are lost
when device is
powered down
Switch 7 has
been toggled
and
user-entered
parameters
have been reset
to factory default
Reset one or more parameters and
cycle power to module. If
parameter altered has remained in
memory, re-configure remaining
parameters.
Do not change the
position of switch 7 to attempt to
rectify this situation. See Chapter
3, Installation, for details.
NVRAM may be
defective
If NVRAM is defective, call
Cabletron Systems Technical
Support.
Condition
Possible Cause
Recommended Action
ICH1Book Page 4 Thursday, April 18, 1996 7:21 AM
Summary of Contents for ESXMIM
Page 1: ...ESXMIM ESXMIM F2 ETHERNET SWITCH MODULE INSTALLATION GUIDE...
Page 2: ......
Page 14: ...Chapter 1 Introduction 1 6 ESXMIM ESXMIM F2 Installation Guide...
Page 54: ...Chapter 4 Troubleshooting 4 6 ESXMIM ESXMIM F2 Installation Guide...
Page 60: ...Appendix B BRIM EPIM Information B 4 ESXMIM ESXMIM F2 Installation Guide...
Page 72: ...Appendix D Ethernet Cabling Requirements D 6 ESXMIM ESXMIM F2 Installation Guide...
Page 76: ...Index Index 4 ESXMIM ESXMIM F2 Installation Guide...