9C300-1 Environmental Module Operation
3-14
Select <ACKNOWLEDGE> after reading all alarms to reset the front panel
ALARM LED (red to green). Selecting <ACKNOWLEDGE> deletes all alarms
and resets the alarm pending banner on line 4 of the non-interactive screens.
Select <EXIT> to return to the Main Screen.
The System Screen
Select the <SYSTEM> option field in line 4 of the Main Screen, as shown in
Figure 3-13, to access the System Screen as shown in Figure 3-15. This screen
displays information specific to the MMAC-Plus chassis. Lines 1 and 2 display the
MMAC-Plus chassis Internet Protocol (IP) address and Media Access Control
(MAC) address.
Line 3 displays the current chassis hardware revision and serial number.
Line 4 lists the following five submenus. Access a specific submenu by selecting it
on the screen.
<PWR>
Displays general power supply configuration information,
with the option to view statistics on specific power supply
modules.
<ENV>
Displays environmental information about the chassis.
<COM>
Displays statistics and information about the front panel
COM ports and EPIM on the Environmental Module.
<DIAGS>
Displays the results of power-up or restart diagnostic tests.
<BBU>
Displays status of BBUs, if they are installed.
Figure 3-15. The System Screen
Select <EXIT> to return to the Main Screen.
CHASSIS MAC ADDRESS xx-xx-xx-xx-xx-xx
<PWR> <ENV> <COM> <DIAGS> <BBU> <EXIT>
CHASSIS HW REV xxx SN xxxxxxxxxxxx
CHASSIS IP ADDRESS xxx.xxx.xxx.xxx