Operation
80-14004000-01
2–3
ALERT System Clock
Sends an ALERT indicating the state of the
System Clock. There are three possible
messages associated with this ALERT :-
ALERT System clock free running
(When No BRI is in Sync or when the BRI that
was supplying system clock loses sync)
or
ALERT System clock gained from
BRI-n
(When a BRI acquires sync and provides
system clock)
or
ALERT System clock lost from BRI-n
(When a BRI loses sync and the next source
is hunted as appropriate)
Where n is the port number, 1 to 4
These ALERTs are only generated when the
CBUQBR is in Clock Master mode.
ALERT B-Channel
usage
Sends an ALERT indicating how many ‘B’
channels are in use. The ALERT message is:
ALERT B-Channel usage x,y
Where x and y are in the range 0 - 8 and :-
x is the number of channels in use
and y is the number of channels remaining
available
x + y = 8
These ALERTs can all be individually enabled or disabled. The Default is
Enabled.