background image

 

i

Notice

 

Notice

 

Cabletron Systems reserves the right to make changes in specifications and other information 
contained in this document without prior notice. The reader should in all cases consult Cabletron 
Systems to determine whether any such changes have been made.

The hardware, firmware, or software described in this manual is subject to change without notice.

IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, 
SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED 
TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION 
CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR 
SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.

© Copyright March 1998 by:

Cabletron Systems, Inc.
35 Industrial Way
Rochester, NH 03867-5005

All Rights Reserved
Printed in the United States of America

Order Number: 9031156-02

 

LANVIEW 

 

is a registered trademark, and 

 

SmartSwitch 

 

is a trademark of Cabletron Systems, Inc.

 

CompuServe

 

 is a registered trademark of CompuServe, Inc.

 

i960 microprocessor

 

 is a registered trademark of Intel Corp.

 

Ethernet

 

 is a trademark of Xerox Corporation.

Summary of Contents for 9C214-1

Page 1: ...SmartSwitch 9000 9C214 1 AC Power Supply Installation Guide 9031156 02...

Page 2: ......

Page 3: ...AMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HA...

Page 4: ...in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible fo...

Page 5: ...Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above di...

Page 6: ...Notice iv...

Page 7: ...ing Up the 9C214 1 Power Supply 2 3 Chapter 3 9C214 1 Power Supply Operation Operating Functions 3 1 System Diagnostic Controller 3 1 Internal Temperature Sensor 3 2 Power Supply Cooling 3 2 LANVIEW L...

Page 8: ...Contents vi...

Page 9: ...or unpacking installing and powering up the 9C214 1 power supply Chapter 3 9C214 1 Power Supply Operation contains detailed information regarding the power supply operation Chapter 4 Specifications pr...

Page 10: ...1 1 The 9C214 1 Power Supply 100 125v 12A 200 250v 6A 50 60 Hz 9C214 1 100 50 0 Load POWER SUPPLY MODULE STATUS P W R S N B Status LED Power Supply SMB Status LED Power Supply Level Indicator LED Powe...

Page 11: ...in each 9C214 1 power supply This circuit protects the power supply from overheating if a thermal overload occurs Automatic recovery takes place after the thermal overload condition is corrected Load...

Page 12: ...t variety of power options the 48 volt DC System Power Bus and all components that use this bus are capable of operating using voltage ranging from 40 60 volts DC This capability allows the SmartSwitc...

Page 13: ...nd revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if know...

Page 14: ...Introduction 1 6...

Page 15: ...m the protective plastic bag Save the bag in the event the power supply must be reshipped 3 Examine the power supply carefully checking for damage If any damage exists DO NOT install the power supply...

Page 16: ...assis remove the power supply realign it and push it in again d Secure the power supply to the chassis by tightening the two screws on the top and two screws on the bottom of the power supply For prop...

Page 17: ...AC receptacle Turn on the power supply using the switch located near the power socket The power supply uses a soft start feature and does a pre power diagnostic check Outputs become enabled within 5...

Page 18: ...Installing the 9C214 1 Power Supply 2 4...

Page 19: ...throughout the chassis for each installed module and the Environmental Module system fans 5 volts supplied to the Diagnostic Power Bus used by the diagnostic controllers and the Environmental Module...

Page 20: ...emote management Power Supply Cooling Each 9C214 1 power supply includes an internal cooling fan The System Diagnostic Controller monitors the internal temperature of the power supply and increases or...

Page 21: ...nd 3 3 volt outputs are within established tolerances Yellow Crippled Not fully operational 57 volt output is not within established tolerances due to lack of AC input Red Fault One of the system powe...

Page 22: ...cription 1 5 Green 10 50 of power load being used No action necessary 6 9 Green 60 90 of power load being used No parallel power supply operational No action necessary 6 9 Yellow 60 90 of power load b...

Page 23: ...ss A EN 55022 Class A VCCI Class I EMC requirements of EN 50082 1 IEC 801 2 ESD IEC 801 3 Radiated susceptibility IEC 801 4 EFT Service The 9C214 1 power supply is designed with the following service...

Page 24: ...5 cubic meters of air per minute drawn through the chassis 76 cubic feet of air per minute drawn through the chassis Universal AC Input Each 9C214 1 power supply accepts input voltage ranging from 100...

Page 25: ...tor is an IEC type entry requiring the use of the Cabletron approved power cord provided with the 9C214 1 power supply Output Voltage Each 9C214 1 power supply is capable of generating the following o...

Page 26: ...Specifications 4 4...

Reviews: