32
33
SUBWAY
USER’S HANDBOOK
SAFETY RULES
• Do not stand in the movement area of the gate.
• Do not let children play with controls and near the gate.
• Should operating faults occur, do not attempt to repair the
fault but call a qualified technician.
EMERGENCY MANUAL OPERATION
In case of power failure or malfunction, the gate leaves can
be moved by hand as follows:
Models with standard lever release, SB.SL (Fig.1)
- remove the plastic cap T by pressing on its edge.
- insert the key C supplied and turn it.
- keeping the key turned, push the gate leaf until it rotates
by some degrees.
- remove the key and place the caps again. The gate will
lock again automatically as soon as it is moved to the initial
position or when the motor is restarted.
Models with customized key release, SB.SK (Fig.2)
- remove the protection pressure cap ”T” of the lock.
- insert key ”C” and turn it until it becomes hard to rotate.
- turn lever ”L” in either direction until a limit switch is
reached.
The gate leaf can be now opened and closed by hand.
To reset the automatic movement, move level “L” to the
original position, turn and extract the customized key ”C”
and close cap ”T” again. The first operation will reset the
normal operation.
Models without mechanic release (SB.BUSH)
As they are reversible, these models simply require the elec-
tric lock to be released. The gate leaf can be then moved
by hand.
Push the leaf by acting with moderation at one end, accom-
panying the gate along its entire stroke.
WARNING: in the manual phase, the gate leaf is com-
pletely free and can be subject to sudden movements.
MAINTENANCE
• Every month check the good operation of the emergency
manual release.
• It is mandatory not to carry out extraordinary maintenance
or repairs as accidents may be caused.
These op-
erations must be carried out by qualified personnel only.
• Periodically check safety components and any other parts
of the system that may become hazardous if worn.
WASTE DISPOSAL
If the product must be dismantled, it must be disposed ac-
cording to regulations in force regarding the differentiated
waste disposal and the recycling of components (metals,
plastics, electric cables, etc..). For this operation it is advis-
able to call your installer or a specialised company.
WARNING
All CAB products are covered by insurance policy for any
possible damages to objects and persons caused by con-
struction faults under condition that the entire system be
marked CE and only CAB parts be used.
T
C
1
2
T
C
L
Summary of Contents for SUBWAY SB.25AC
Page 2: ...1 2 3 11 8 9 10 6 12 7 13 14 15 4 2 3 16 17 5 C 2 1 2 3 228 mm 400 mm 320 mm 50 mm...
Page 4: ...4 OPEN OPEN 100 100 10 SX DX 13 11 SX OPEN OPEN DX 12 V V G B 14 15 G B SX OPEN OPEN DX...
Page 6: ...6 19 OPEN CLOSE T T SX DX OPEN OPEN CLOSE CLOSE 20 V G 21 A B B A L...
Page 31: ...31 SB FB 1 2 3 5 4 6 7 8 9 10 10 11 11 12 13 14 15 16 17 18...
Page 38: ......
Page 39: ......