background image

12

12

Error Messages

4.1 

Error Messages of the Printer

For detailed information about printer errors (e.g. 'Paper out', 'Ribbon out', etc.) 

 Check the operator's manual of the 

printer.

Error treatment:

 

Clearing the error results.

 

Press the 

feed

 key to synchronize the label feed, remove the left over labels manually.

 

Press the 

pause

 key to quit the error state.

After error correction, the label causing the error will be reprinted.

4.2 

Error Messages of the Applicator

The following table contains an overview of applicator specific error messages and their possible causes. It also 

suggests methods to resolve the problems:

Error Message

Possible Cause

Air pressure ins.

Compressed air is switched off
Pressure to low < 4 bar
Pressure to high > 6 bar

Label not depos.

Label has not been placed onto the product; after the pad has moved back the label is 
still sticking to the pad.

Lower position

Pad has not reached the starting position within 2s after the pad has left the labelling 
position; or pad has left  the starting position without authorization.

Process Error

Process of labeling was interrupted via the I/O interface of the printer with the  XSTP 
signal.

Refl. sensor blk.

There has been no change of the switch state at the upper sensor at the cylinder 
between the start of the labelling process and the signal from the labelling position 
sensor.

Upper position

Pad is not in the starting position when the printer is switched on.
Pad has not reached the labelling position within 2s after the movement of the pad was 
started.
Pad has left the printing position without authorization.

Vac. plate empty

Label has not been picked up properly by the pad; or label fell off the pad before it could 
be placed onto the product.

Table 2 

Error messages of the applicator

Error treatment:

 

Clear the error results.

 

Press the 

pause

 key to quit the error state. 

i

Note!

In the case of errors check the 

 Service Manual for adjustment and settings.

!

Warning!

After the error has been resolved the pad will immediately move back to the starting position!

Danger of crushing hands and fingers by the moving pad! 

 

Do not reach into the zone of the moving pad and keep long hair, loose clothes, and jewelry distant.

After error correction, the printing of the label causing the error cannot be repeated without restarting the print job 
except the error "

Vac. plate empty"

 .

 

In this case, the last label will be printed again after resolution via the 

pause

 key and then pressing the Enter button   .

 

In the application mode "Apply/Print" sends the signal "Print first label" or press the button 

  to send a printed 

label to the tamp.

Summary of Contents for 4126C

Page 1: ...Made in Germany Assembly Instruction 4126C 4136C Stroke Applicator ...

Page 2: ...r Please check www cab de for the latest update Terms and conditions Deliveries and performances are effected under the General conditions of sale of cab Assembly instructions for the following products Germany cab Produkttechnik GmbH Co KG Karlsruhe Phone 49 721 6626 0 www cab de USA cab Technology Inc Chelmsford MA Phone 1 978 250 8321 www cab de us Taiwan cab Technology Co Ltd Taipei Phone 886 ...

Page 3: ...scription 6 2 1 Important Features 6 2 2 Technical Data 6 2 3 Function 7 2 4 Overview 8 2 5 Contents of Delivery 9 3 Operation 10 3 1 Standard Operation 10 3 2 Cleaning 10 4 Error Messages 12 4 1 Error Messages of the Printer 12 4 2 Error Messages of the Applicator 12 5 Licences 13 5 1 Declaration of Incorporation 13 5 2 EU Declaration of Conformity 14 ...

Page 4: ...and the recognized safety rules However danger to life and limb of the user or third parties and or damage to the device and other tangible assets can arise during use The device may only be used for its intended purpose and if it is in perfect working order and it must be used with regard to safety and dangers as stated in the operating manual The device applicator mounted on a cab printer of the...

Page 5: ...ervice technicians Unauthorized interference with electronic modules or their software can cause malfunctions Other unauthorized work on or modifications to the device can also endanger operational safety Always have service work done in a qualified workshop where the personnel have the technical knowledge and tools required to do the necessary work There are various warning stickers on the device...

Page 6: ...from the side from the top from below from the side Compressed air pressure bar 4 5 4 5 4 5 4 5 Blow tube number 1 1 2 2 Cycle time about frequency aprox labels min 1 20 20 20 20 Tamp pad 4126C 11 F 4126C 12 F 4126C 19 F Label width mm 46 174 Label height mm 20 100 Product distance to lower edge up to mm 220 320 Immersion depth pad F2 mm 90 Product during labeling fixed Tamp pad spring loaded 4126...

Page 7: ...inder retracted mini lift cylinder extended main lift cylinder retracted mini lift cylinder retracted intermediate stop main lift cylinder retracted mini lift cylinder retracted main lift cylinder retracted mini lift cylinder extended labeling position main lift cylinder extended mini lift cylinder retracted main lift cylinder extended mini lift cylinder extended Fig 2 Function of the applicators ...

Page 8: ...mpressed air connector 3 Shutoff valve 4 mini lift cylinder with lift pad support 5 Blow tube for supporting air 6 Upper holes for attaching on the printer 7 SUB D 15 Interface to the printer 8 Lower holes for attaching on the printer y x z 2 Product Description Front View y x z ...

Page 9: ...ad 4 Pad as ordered 5 Documentation Fig 4 Contents of delivery i Note Please keep the original packaging in case the applicator needs to be returned Attention The device and printing materials will be damaged by moisture and wetness X Only set up the label printer with applicator in dry locations protected from moisture and splashes ...

Page 10: ...d is initiated The processed labels have to be removed manually After a few seconds the printer carries out a short backward feed to position the front edge of the next label at the printing line i Note The synchronization also has to be carried out when the print job has been interrupted with the cancel key Synchronizing is not necessary when the print head was not lifted between print jobs This ...

Page 11: ...ther alignment elements This will enable use of the applicator directly after cleaning Turning away dismounting the applicator 1 To turn away the applicator loosen thumbscrew 5 and swing the applicator to the side 2 Disconnect SUB D 15 male connector 6 from the female connector 7 of the printer 3 Loosen screw 4 and move the locking plate 3 from the hinges 4 Lift the applicator upward and off the p...

Page 12: ...of the switch state at the upper sensor at the cylinder between the start of the labelling process and the signal from the labelling position sensor Upper position Pad is not in the starting position when the printer is switched on Pad has not reached the labelling position within 2s after the movement of the pad was started Pad has left the printing position without authorization Vac plate empty ...

Page 13: ...EN ISO 12100 2010 EN ISO 13849 1 2008 EN 60950 1 2006 A11 2009 A12 2011 A1 2010 A2 2013 Other Relevant Directives Directive 2014 30 EU relating to electromagnetic compatibility Directive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment Person authorised to compile the technical file Erwin Fascher Am Unterwege 18 20 99610 Sömmerda Signe...

Page 14: ...ade invalid Device Stroke Applicator Type 4126C 4136C Applied EU Regulations Applied Standards Directive 2014 30 EU relating to electromagnetic compatibility EN 55022 2010 EN 55024 2010 EN 61000 6 2 2005 Directive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment EN 50581 2012 Commission delegated directive EU 2015 863 amending Annex II...

Reviews: