Adjusting the Blow Tube (Supporting Air)
The blow tube must be adjusted in such a way that the label takeover is unhindered by turbulence and the supporting
air blows the label evenly against the pad.
The default factory value is 2 bar.
i
Note!
Use an appropriate blow tube for the printer in use.
A number of holes of the blowing tube are covered by plastic rings. It is necessary remove as many of these
rings as are needed to ensure the entire label-width is supported.
1
3
3
5
5
A
B
A
B
2
4
Fig. 18
Adjust the blow tube
The blow tube (3) for the supporting air can be rotated around its axis. That way the direction of the supporting air can
be optimized.
1. Loosen screw (1).
2. Put in the blow tube (2) into the tube adapter A (2).
Turn the blow tube (2) in the direction that the air current can support the take up of the label.
•
For small labels direct the air current more toward the dispensing edge (5) of the printer.
•
For larger labels direct the air current away from the dispense edge (6).
Use the graduation guide for orientation.
3. Open all holes of the blow tube to cover the label width. Remove rings (4) if necessary.
All holes outside the label width should be covered with the shrink tube rings provided. Once the unneeded holes
have been covered the shrink tube should be shrunk.
4. Tighten screw (1).
Summary of Contents for 4114 Series
Page 1: ...Made in Germany 4114 4116 Stroke Applicator Service Manual ...
Page 40: ...40 40 11 Drawings 11 2 Pneumatic Drawing Type 4114 Fig 41 Pneumatic drawing type 4114 ...
Page 41: ...41 11 Drawings 11 3 Pneumatic Drawing Type 4116 Fig 42 Pneumatic drawing type 4116 ...
Page 42: ...42 42 11 Drawings 11 4 Label Position Type 4114L 4116L Fig 43 Label position 4414L 4116L ...
Page 43: ...43 11 Drawings 11 5 Label Position Type 4114R 4116R Fig 44 Label position 4114R 4116R ...