IMPORTANT
: The batteries of this device have been pre-charged by the Manufacturer so that device can be used
immediately by user. In case instead that device immediately indicates low battery when first switched on (blue light
flashing quickly), it is necessary to proceed as soon as possible with a full charge cycle of internal battery.
3.2.1 How to recharge internal battery
A)
When the batteries are low (rapid flashing of the BLUE light on the product front side), connec
t the device to the
supplied DC power supply and place the device horizontally on a flat and stable surface, away from heat sources.
Then connect the power supply to the power outlet to begin the charging cycle of internal battery.
B)
When the power supply is connected to the power outlet, a YELLOW light will light up on the bottom of the
device to indicate
that the internal battery charging cycle has started regularly. When the charging cycle is complete
(battery fully charged) the Yellow light will be re
placed by a GREEN light. The charging times changes according to
the initial level of charge of the batte
ry. With fully discharged batteries, the full charge time lasts approximately 4
hours (100% charge).
C) The recharging will stop if the device is turned on for nebulization during recharging. Do not stop charging cycle
unless urgently needed.
IMPORTANT
GENERAL ADVISE:
ALWAYS RECHARGE THE BATTERY WITHIN 1 MONTH FROM THE AUTOMATIC
SHUTDOWN FOR LOW CHARGE. IF THE BATTERY IS LEFT COMPLETELY
DISCHARGED FOR MORE THAN A MONTH, IT MAY BE DAMAGED PARTIALLY OR
TOTALLY
THE BATTERY CAN BE CHARGED FOR A MAXIMUM OF 300 TIMES UNTIL FULLY
REACHING ITS FUNCTIONAL SPECIFICATIONS. WHEN MAINTAINED AND USED
CORRECTLY, SUBSEQUENT RECHARGES OF BATTERY ARE
POSSIBLE BUT IN
FUNCTION OF ITS GENERAL INTEGRITY CONDITIONS, THEY MAY PROVIDE LESS
AUTONOMY OF USE. ONCE THE BATTERY IS OUT, THE DEVICE CAN ONLY
OPERATE WITH THE POWER SUPPLY.
IMPORTANT: For a longer durability and to best exploit battery performance, it is recommended
not to carry out partial charges and to recharge the internal battery only when it is discharged
(rapid flashing of the front BLUE LED and / or automatic switch
-
off for low battery).
4 –
USING THE DEVICE
Once properly prepared, the device is very easy to use. Just press the ON/OFF button on the front panel to turn the
device on or off.
Summary of Contents for KIWI Plus
Page 1: ...1...
Page 6: ...6 KIWI Plus MESH PC 200 0 1 ml 93 MMAD 1 51 m CA MI 1 2 3...
Page 7: ...7 4 5 6 KIWI Plus 7 8 9 ISO 10993 1 10 EN 60601 1 11 12 13 14...
Page 8: ...8 15 93 42 EEC...
Page 9: ...9 1 8 ml 8 cc 12 ml 8 ml...
Page 10: ...10 2 4 L S...
Page 12: ...12 3 2 100 220 28 1 1 2 5 ml NaCl 0 9 300 1 100 3 2 1 DC 4 100 1 300...
Page 13: ...13 LED 4 20 90...
Page 14: ...14 1 1 1...
Page 15: ...15 2 1 2 5 3 30 4 Y 10...
Page 17: ...17 2 180 5 2 1 0 3 2 3 4 5 1 2 3 4 5...
Page 20: ...20 CA MI Srl 24 CA MI srl CA MI srl 93 42 BF II AC DC...
Page 21: ...21 IPX2 1 2 15 2006 66 2012 19...
Page 57: ...57...