5.2 Decoder Panel
HDMI OUT
RESET
IR IN
DC 5V
CAT IN
Connect to HDMI display device such as TV or
monitor with an HDMI cable.
Number
Name
Function description
1
HDMI OUT
1
2
3
4 5 6
7
2
RESET button
▪
Press the button briefly to reset the product, including
IP address, encoding information and EDID. The
EDID will recover default status for 1920*1080@60Hz
.
▪ Press the button up to 3 seconds to copy EDID
from Decoder display device to Encoder’s HDMI
source device.
3
CAT IN
The CAT IN port is connected CAT OUT port at the
Encoder or connected switcher /
router / hub with
CAT cable for receiving Encoder signal.
4
IR IN
Connect to wideband IR receiver cable. The IR signal
is sent to IR OUT port at the Encoder.
5
LINK LED
The LED will flash blue when Decoder is connected
Encoder or connected switcher /
router / hub.
6
POWER LED The LED will illuminate blue when the Decoder is
powered on.
7
DC 5V
Plug the DC 5V/1A power supply into the unit and
connect the adapter to an AC outlet.