Chap 6 Glossaries
Programming extension-----------------Extension No.11, 12, 13, 14
N-----------------------------------------------Series number of the extensions (1-8 with corresponding input ports 1-8) (one digits)
abcd------------------------------------------Number of the extension(1-8999,except for the digits with the first digit of 0 or 9,outward
code of special trunk line, in equal length)is accordance with N.
M-----------------------------------------------Series number of the exterior line (No.1-3with corresponding input ports of Line 1- 3,
thereinto,108---M=1; 206---M=1-2; 308---M=1-3)
P-----------------------------------------------Licensed Group Number (01-16)
Q-----------------------------------------------First-digit restrict group number (01-16)
ABCD-----------------------------------------Licensed or restricted number of first 1-4 digits, end for #
L-----------------------------------------------Service grade (Grade of private passwords or outgoing call), grade 0-6
TT----------------------------------------------Time in minute for call duration control, ranges from (01 to 99)
F------------------------------------------------Flash time class.
Chap 7 Default Settings
•
C.O. line: 108 is in Enable status; 206/308 are in Disable status.
•
Operating mode: All C.O. line in Operator mode, but 108 doesn’t has auto-attendant mode.
•
Dialing out mode: 108 is in Direct-Dialing-Out mode; 206/308 is in Indirect-Dialing-Out mode, dialing “9” for
outgoing
•
All C.O. lines are ungrouped
•
Operator: Ext. 12
•
Ring Ext.: 108: All Exts. ring together; 206/308: Ext.11 and Ext.12 ring.
•
Extension service class assignment: 2
•
Time Restriction: No
•
Flash time: 1.0s
•
Outgoing Exts. Assign to Certain C.O. lines: No
•
Original EXT number: 11 to 18
•
Restrict Item A / Item B: No setting
•
Special Calling-out Number: No setting