CLIMEXEL HEAT PUMPS MANUAL

 

pag. 9 di 18 

www.cpa-piscine.it 

Ver.02

2017-08-04 

 

 

 

 

 

Button 

Function 

 

 
 

 

 

Push and release: 

The Set point value is shown in cooling (SetC code) and in heating (SetH code) 

Press and hold for 3 seconds: 

The Set point value is shown 

Press and release in programming mode: 

Allows you to access the modification of the parameters 

Allows the acceptance of the new parameters 

 

 

 

Push and release: 

The value read by the sensor is shown 

Press and release in programming mode: 

Scroll through the parameters 

While editing, the parameter value changes 

 

 

 

Push and release: 

The value read by the sensor is shown 

Press and release in programming mode: 

Scroll through the parameters 

While editing, the parameter value changes 

 

Push and release: 

Starts and stops the machine in cooling mode 

 

Push and release: 

Starts and stops the machine in heating mode 

 
 

 
 

 

 

Push and release: 

Entering and exiting the menu, allows you to access the following parameters: 

 

ECO / CONFRT mode 

 

Display and reset of active alarms 

 

Pout parameter: shows the "Step" power level 

 

Activation and deactivation of "slave" mode of the "Ser" filtration pump (optional) 

 

UPL parameter: factory settings 

 

ALOG parameter: factory settings

 

Press and release in programming mode: 

Returns to the previous programming level 

2. 

CONTROL KEYPAD FUNCTIONS

 

Summary of Contents for CLIMEXEL Series

Page 1: ...MANUAL Ver 02 2017 08 04 C P A S R L MANUALE HEAT PUMPS CLIMEXEL SERIES...

Page 2: ...SPLAY CORRECT WORKING 11 6 DISPLAY SIGNAL OF ANOMALY 11 7 STOP 11 8 SET POINT DISPLAY AND PROGRAMMING 12 9 ECO COMFORT MODE SELECTION 12 10 SETTINGS AND CONTROLS 13 A CHECKING THE FLOW THROUGH THE BY...

Page 3: ...al to ensure optimal operation Usually the points to be respected are the following The heat pump must be imperatively installed outdoors and a minimum distance must be respected with any type of wall...

Page 4: ...llation prepare a concrete slab about ten cm thick at least the same size as the base of the machine Installation at height the support and its fixing on the wall must resist the weight of the machine...

Page 5: ...am of the filter to minimize greasing of the exchanger and upstream of any injection of chemical products for disinfestation and pH regulation provide a space of 1 5 meters of pipes such as minimum to...

Page 6: ...nded that the heat pump is not moved more than 10 metres away from the swimming pool Beyond a certain length the pipes must be buried at a sufficient depth take into account the risk of ground frost a...

Page 7: ...ine must be wired via the white connection box located next to the information plate Remove the protective wrapping Remove the 4 plastic screws from the cover of the connection box to release and remo...

Page 8: ...e Display the inlet and outlet water temperature and the room temperature Display alarms indicate a defrosting cycle The machine s support base must have a very slight slope approx 1 2 towards the cor...

Page 9: ...ue changes Push and release The value read by the sensor is shown Press and release in programming mode Scroll through the parameters While editing the parameter value changes Push and release Starts...

Page 10: ...fficient water flow Appears when the compressor is running Appears when the filtration is in series with the heat pump optional Appears when the defrost function is active while the ambient temperatur...

Page 11: ...18 www cpa piscine it Ver 02 2017 08 04 6 DISPLAY SIGNAL OF ANOMALY 7 STOP Press to stop the pump when it is in cooling mode Press to stop the pump when in heating mode Display con macchina in spegni...

Page 12: ...he screen Set point selection 1 Press and hold the SET SET key for 3 seconds 2 The current set point is displayed on the screen flashing 3 Use the or keys to select the new setting 4 Save the setting...

Page 13: ...scina o aumenter con l aumentare della temperatura dell aria ambiente e o diminuir la temperatura dell acqua da piscina To regulate the flow rate of the by pass loop the machine must be operating at f...

Page 14: ...e air to the heat transfer fluid The heat pumps are equipped with a device that automatically detects the excessive accumulation of ice and triggers the defrost by inversion of the cycle The defrostin...

Page 15: ...set point correct Value entered correctly Is filtration running The heat pump starts up but the earth leakage circuit breaker trips Is are the earth leakage circuit breaker or thermal magnetic circui...

Page 16: ...ost cycle correctly o Does the thermodynamic defrosting phase start Acoustic sound change in compressor pitch and partial ice melting o Ice remains on the bottom of the evaporator condensate does not...

Page 17: ...at least 5 minutes EE EEPROM alarm Loss of date from the thermostat s EEPROM memory Replace in thermostat ACF1 Configuration alarm Incorrect configuration of the thermostat Input and or output temper...

Page 18: ...the technical requirements required by the specific regulations on the subject By qualified personnel we mean those people who due to their training experience and education as well as their knowledg...

Reviews: