Test for battery voltage at  B+ terminal on alternator to ground, then at F+ terminal on regula-
tor to ground. Does battery voltage exist?

Yes

No

Repair vehicle wiring as necessary. Continue test.

Vehicle charging circuit test is complete.
Remove jumper wire. Run engine and
re-test charging circuit for operation.

Chart 2 – No Alternator Output – 

Ener

Ener

Ener

Ener

Energize Switch

gize Switch

gize Switch

gize Switch

gize Switch

 – Test Charging Circuit

Jumper B+ terminal on alternator to E terminal
on regulator. Touch shaft with steel tool to detect
significant magnetism. Is shaft magnetized?

Yes

No

Go to energize switch on engine in E circuit.
Test for battery voltage going into energize switch
from battery. Does battery voltage exist?

Yes

No

Make sure jumper wire from alternator B+
terminal to regulator E terminal is still attached.
Test for battery voltage at energize switch E
terminal connection. Does battery voltage exist
at energize switch?

E circuit from regulator
to energize switch is
good. Energize switch is
defective.

Repair vehicle circuit to
energize switch. Continue test.

Yes

No

Repair vehicle circuit
from E teminal on
regulator to energize
switch on engine.

     

  ­

€‚ƒ„

 
  
  
 
 

Yes

Unplug alternator-to-regulator harness. Plug CEN
Regulator Bypass Adapter A10-129 into harness
plug. Make sure black lead does not touch
ground. Clip red lead to B+ terminal on alternator.
(If Adapter is not available, connect jumper wire
from socket B on harness to alternator B+ termi-
nal.) Does spark occur at alternator B+ terminal?

Disconnect Regulator Bypass Adapter or jumper
wire. Connect DMM red lead to socket E in alter-
nator-to-regulator plug. Connect black lead to
socket A in same plug. Does battery voltage exist?

Regulator is defective.

Yes

No

Disconnect Adapter or jumper
wire. Alternator is defective.

No

Alternator is defective.

Touch black lead to ground on alternator case.
(If Adapter is not available, connect jumper wire
from socket C on harness to ground.) Spark will
occur at ground. Touch steel tool to shaft to
detect significant magnetism. Is shaft magne-
tized?

Yes

No

Disconnect Adapter or jumper
wire. Alternator is defective.

R

Section 3: Advanced Troubleshooting (cont.)

Page 5

TG7B

Summary of Contents for C815

Page 1: ...sure the meter leads touch source area only Prevent short circuit damage to test leads or source by not allowing meter leads to touch other pins or exposed wires in test area Be sure to use CEN tools...

Page 2: ...vehicle electrical loads are switched on and off Alternator output current is self limiting and will not exceed rated capacity of alternator A2 128 regulator used with all units has R terminal for op...

Page 3: ...ack lead to alternator B terminal Clamp inductive ammeter on B cable 6 Operate vehicle Operate vehicle Operate vehicle Operate vehicle Operate vehicle Observe charge voltage If voltage is at or below...

Page 4: ...ch ignition switch ignition switch ignition switch go to Chart 3 page 6 Is there a battery isolator in the system Chart 1 System Circuit Install temporary jumper between one battery terminal and alter...

Page 5: ...egulator to energize switch is good Energize switch is defective Repair vehicle circuit to energize switch Continue test Yes No Repair vehicle circuit from E teminal on regulator to energize switch on...

Page 6: ...es No Repair vehicle wiring as necessary Continue test Yes Unplug alternator to regulator harness Plug CEN Regulator Bypass Adapter A10 129 into harness plug Make sure black lead does not touch ground...

Page 7: ...tor or any of these test procedures or if you need to locate a Factory Authorized Service Distributor please contact us at C E Niehoff Co 2021 Lee Street Evanston IL 60202 USA TEL 800 643 4633 USA and...

Reviews: