background image

TG0007A

C. E. Niehoff & Co.

BRUSHLESS ALTERNATORS


 

The

C715

C715

C715

C715

C715

 alternator (14 V, 360 A) and 

C716

C716

C716

C716

C716

 alterna-

tor (14 V, 400 A) are internally rectified. All windings
and current-transmitting components are non-
moving, so there are no brushes or slip rings to wear
out. This unit is externally energized through either
an ignition switch or an energize switch (commonly
an oil pressure switch), which activates regulator.
Field coil is then energized. Regulator maintains
alternator output voltage at regulated setting as
vehicle electrical loads are switched on and off.
Alternator output current is self-limiting and will not
exceed rated capacity of alternator.
A2-128 regulator used with all units has R terminal
for optional AC voltage tap. A 15.5 V regulator set-
point is available for battery isolator applications.
Electromagnetic interference (EMI) is suppressed with
internal filters to acceptable levels defined by the
Society of Automotive Engineers (SAE) specification
J1113/41. A2-128 regulator will not reduce EMI from
sources such as antennas, poor cable routing prac-
tice, or other electronic devices that cause EMI. If EMI
continues, consult an electromagnetic compliance
(EMC) specialist to determine EMI source.

 

R

Section 1: Wiring Diagram

Page 2

TG7B

Summary of Contents for C815

Page 1: ...sure the meter leads touch source area only Prevent short circuit damage to test leads or source by not allowing meter leads to touch other pins or exposed wires in test area Be sure to use CEN tools...

Page 2: ...vehicle electrical loads are switched on and off Alternator output current is self limiting and will not exceed rated capacity of alternator A2 128 regulator used with all units has R terminal for op...

Page 3: ...ack lead to alternator B terminal Clamp inductive ammeter on B cable 6 Operate vehicle Operate vehicle Operate vehicle Operate vehicle Operate vehicle Observe charge voltage If voltage is at or below...

Page 4: ...ch ignition switch ignition switch ignition switch go to Chart 3 page 6 Is there a battery isolator in the system Chart 1 System Circuit Install temporary jumper between one battery terminal and alter...

Page 5: ...egulator to energize switch is good Energize switch is defective Repair vehicle circuit to energize switch Continue test Yes No Repair vehicle circuit from E teminal on regulator to energize switch on...

Page 6: ...es No Repair vehicle wiring as necessary Continue test Yes Unplug alternator to regulator harness Plug CEN Regulator Bypass Adapter A10 129 into harness plug Make sure black lead does not touch ground...

Page 7: ...tor or any of these test procedures or if you need to locate a Factory Authorized Service Distributor please contact us at C E Niehoff Co 2021 Lee Street Evanston IL 60202 USA TEL 800 643 4633 USA and...