C. Davis Systems
CDS-LC
2.0 SYSTEM DESCRIPTION
Dual Contact Feeder Crimper:
Model #
LC-2208-12GA
Serial #
Contact #
From the front and top of the machine you can reach:
A.
The Feeder Bowl.
B.
The Crimper Assembly, in the center.
C.
The ON button on the top far right
D.
The POWER ON Light on the upper left corner of the
electrical box.
The rear side of the machine houses the male air supply quick disconnect ,the
electrical power cord, and the foot switch.
2.1
Feeder
Vibratory feeder bowl (configured to feed contact listed in the
system description) is mounted to an aluminum base plate with
rubber isolation feet. The contacts are oriented and fed onto an
Escapement mechanism that singulates them and blows them to
the Crimp Head. The Escapement mechanisms have sensors
mounted in them to keep a steady supply of contacts in Que.
When the sensor detects the Escapement is full the feeder bowl
will shut off.
Model #CDS-LC C. Davis Systems Inc. Operations Manual