3.0 Installation
Use the
C-Bus Wiser Home Controller 5200PG Setup Sheet,
provided with
the equipment to do the hardware installation. Consult other Wiser Home
Controller product information for details.
3.1 Installation
Location
It is important to select the best location to install the Wiser Home
Controller. Some considerations are listed below:
•
The Wiser Home Controller is designed for indoor use only.
•
The Wiser Home Controller can be mounted on a wall using the
keyholes on the rear of the router. Refer to the Setup Sheet for
details.
•
Locate the equipment near associated wireless devices for best
reception.
•
Choose a location free of water, humidity, direct sunlight and heavy
dust. Make sure the equipment will have adequate ventilation.
•
Route network cables where they will not be disturbed by people
walking about.
•
Provide a building power point for the power supply.
3.2 Important
Notes
•
Keep the PC network (Ethernet) and C-Bus network isolated from each
other. Do not connect the pink C-Bus network cable to an Ethernet LAN
or telephone lines.
The C-Bus network uses polarised 15 - 36 V d.c. that can
damage PC equipment. Connecting Ethernet network cables to
a C-Bus network will cause the networks to fail. Use pink C-Bus
network cable to avoid confusion.
•
Using software not provided by Clipsal Integrated Systems (CIS) for
C-Bus operation may cause unpredictable results.
•
If you install the CNI unit in a different location from Home Controller,
you must provide a 6-12 V d.c. power supply for the LAN side of the
CNI. You will also use a network cable in place of the extender (busbar).
Polarity for the power socket of the CNI is as follows: