This manual will give you all the information you need to operate and control 

the Securit 700L Control Panel. This manual will NOT tell you how to program 

or configure the control panel, for that see the engineering instructions. 

 

1.0 SETTING 

 

1.1 FULL SET 

( Used when leaving premises ) 

To start the exit procedure ensure all alarmed zones are clear. Now enter 

your four digit user code, the buzzer will emit a steady sound and the exit time 

start. 

Leave the building by the approved exit route and close the final exit door. 

Wait 

outside the door until the buzzer has stopped to indicate that the panel has 

armed. 

If any zones are in fault the buzzer will pulse and the LED for that zone will be 

lit. Return to the panel and press the "#" key or enter the user code to abort 

the exit 

procedure. Investigate the fault and correct if possible, then start the exit 

procedure 

again. If you are unable to correct the fault contact your alarm Installation 

company. 

If you do not complete the exit procedure before the exit time runs out the 

internal 

sounder will start. Enter your user code to stop the sounder. See section 3.3 

to reset 

the control. 

1.2 PART GUARD 

( Used when going to bed ) 

Start the exit procedure as for full set as above. Then press the "*" key 

followed by the "0" key. The buzzer will change tone to a lower, deeper sound 

and 

the LED's for any zones programmed to be isolated in part guard will flash. 

The 

programmed part guard exit time will be selected and the exit procedure will 

continue. If when performing this procedure you delay for more than 3 

seconds 

between the "*" and the "0" then an error tone will be heard. Restart the exit 

procedure followed by "*" then "0" and continue with your exit procedure. 

1.3 MANUAL ISOLATION 

( Used to switch off various zones ) 

Start the exit procedure as for full or part set as given above. Then press the 

"*" key followed by the number of a zone you require to isolate. If the zone is 

accepted is will now isolate and the LED for that zone will flash and the exit 

procedure will continue. If you require any further zone to be isolated then 

again 

press "*" followed by a zone number. Again the time between "*" and a zone 

number 

must not exceed 3 seconds or it will be classed as an error or mis-key and it 

will be

 

This manual is from 

Technical Manuals Online! - http://www.tech-man.com

Summary of Contents for Securit 700L

Page 1: ...This manual is from http groups msn com UKSecurityPanels Technical Manuals Online http www tech man com ...

Page 2: ... start Enter your user code to stop the sounder See section 3 3 to reset the control 1 2 PART GUARD Used when going to bed Start the exit procedure as for full set as above Then press the key followed by the 0 key The buzzer will change tone to a lower deeper sound and the LED s for any zones programmed to be isolated in part guard will flash The programmed part guard exit time will be selected an...

Page 3: ...l be indicated by the internal AND external sounders going into alarm and also the strobe unit if fitted will begin to flash Enter your four digit user code to unset the system The LED display will indicate which zone caused the alarm See section 3 3 to reset the control panel 3 2 PERSONAL ATTACK ALARMS When a personal attack alarm is triggered it is usually triggered from a button You should go f...

Page 4: ...DAY mode You may end the test at any time by pressing the key 4 3 CHANGING THE USER CODE There are two separate user codes available to the customer A main MASTER code and a secondary user code which can be enabled or disabled by the user By default the second user code will be disabled 1 Master user 2 Second user There are no differences to the usage of these codes They both perform the same task...

Page 5: ... organised as SET and UNSET events All events are recorded The first alarm is shown by the relevant LED being lit continuously Subsequent alarms are shown by a fast pulse of the zone LED Any zones isolated are shown by a slow pulse of the zone LED The buzzer will sound whilst viewing the SET logs but will be silent whilst viewing the UNSET logs Pressing the 0 key while reviewing the logs will show...

Page 6: ... sounder will stop and the zone LED will go out The buzzer will emit a low level steady tone as before Report any faults to your alarm installation company Press the key to finish The following is given so a record of your zone configurations can be made simply fill in where each zone is located in your premises THE FOLLOWING IS PROVIDED TO GIVE QUICK ACCESS TO VARIOUS PEOPLE IF A PROBLEM OCCURS T...

Reviews: