C H Byron
34, Sherwood Rd
Aston Fields
Bromsgrove
B60 3DR
Contact Details:
433MHz
R&TTE
APPROVED
CH Byron Electrical United Kingdom. www.chbyron.com
A
B
DK
FIN
F
D
GR
LT
IRL
I
L
NL
P
E
S
UK
BG
CZ
EST
H
IS
LV
M
N
SK
SLO
CH
PL
RO
0560
Tel: 0845 2301231
Fax: 01527 557701
Web: www.chbyron.com
E-mail:
No Activation:
-Check the battery life and pairing with receiver socket or
module.
Receiver stays ON
-The PIR might be receiving false signals due to the
continuously:
selected location, try adjusting the angle.
Radom Activation:
-Wind/rain can cause the PIR unit to activate , try a new
location if needed.
-Small animals can activate the PIR.
-Try selecting a new address code.
-Passing traffic or pedestrian can activate the PIR, alter
the detection angle.
Contact:
Helpline: 0845 2301 231
RF Range:
The radio signals operating distance is reduced when the signal has
to pass through walls. The radio signals achieve a range of 25m; this can be
reduced depending on the type of material
TIMBER
CONCRETE
METAL
GLASS
PLASTICS
10 - 15%
BRICK
10 - 40%
40- 80%
10 - 40%
90%
5 - 15%
Range
Reduction Guide:
Detection Area:
Help Section :
Product Specification:
Remote Control: HE-403
Battery: 3 * AAA
Range: 25Metres (Open Distance)
Frequency: 433.92MHz
IP44 Weather Proof
Warning:
Never Exceed the Product Specification
Up to Six remote control units can be paired with each
HomeEasy Receiver socket or module, to pair the
outdoor PIR with a receiver unit, remove the battery
cover and, slide the switch to DEL.
Deleting Remote Control:
To delete the PIR from the memory of a HomeEasy remote control receiver
socket or module, simply press the "Learn" button. The LED will start to blink;
slide the "LEARN" switch to "DEL", the LED will blink twice to confirm that the
remote control has been removed from the receiver sockets memory.
Pairing/Deleting with Remote Control:
Now press the "Learn" button, the LED will start to flash, now slide the
"LEARN" switch to "SET", the units are now paired together.
Setting Timer :
The HomeEasy Outdoor PIR will switch on the receiver socket or module for a
predefined period of time when activated, this can be set between 15 seconds
and 4 minutes.
Timer Setting:
1min:
15 sec:
4 min(max):
The PIR detection area is 110 degrees, this can be reduced using the clip-on
covers (included). if required the covers can be cut to size.
if required the covers can be cut to size.
N/A:
Day/Night Setting:
The PIR can operate in 24Hr a day or night
mode (Low Level Conditions <10Lux). To
select night only mode, remove the cover
from the bottom of the PIR and press the
"LUX" button as shown below.
Remote Socket: HE-310
Max Load: 3000W (Max)
Indoor Use Only
To select the time period, remove the
battery cover and using a small screw
driver rotate the dial to select the
required time.
Remote Socket reset:
To delete all the remote control units from the memory of the receiver
socket, hold the "Learn" button for more than 6 seconds, the LED will start
to blink continuously. Press and hold the "Learn" button again, the LED
will blink twice to confirm that all paired remote controls have been
deleted from the receiver sockets memory.