ByoPlanet MS-700 Operator'S Manual Download Page 3

SAFETY NOTICES

WARNINGS

WARNINGS

WARNINGS

WARNINGS

This manual contains information that is important for you 
to know and understand before operating the ByoPlanet

®

 

MS-700™ Electrostatic Sprayer. This information relates to 
protecting your safety and ensures product reliability and 
performance. It is the owner’s responsibility to ensure that  
all who operate this equipment read this manual.

Warnings

To help you recognize this information we use the warning 
symbols below. Please read the manual carefully, and pay 
special attention to the symbols and warning labels. Warning 
labels indicate a potentially hazardous situation which, if not 
avoided, could result in death or serious injury.

PLASTIC PARTS CLEANING SOLVENT HAZARD 

Many solvents can degrade plastic parts and cause them  
to fail, which can lead to serious injury or property  
damage. In order to help prevent against degradation:

FIRE, EXPLOSION AND ELECTRIC SHOCK HAZARD 

Flammable fumes, such as solvent and paint fumes, in  
work areas can ignite or explode. To help prevent fire,  
explosion  and electric shock:

• 

Use only compatible  
water-based solvents to clean 
plastic structural pressure  
containing parts.

• 

See technical data in this and 
all other equipment instruction 
manuals. Read fluid and solvent 
manufacturer’s Safety Data 
Sheets (SDS) and recommenda-
tions prior to use.

• 

Electrostatic equipment must be 
used only by trained, qualified 
personnel who understand the 
requirements of this manual.

• 

Stop operation immediately if 
static sparking occurs or you feel 
shock. Do not use equipment 
until you identify and correct the 
problem.

• 

Use and clean equipment only  
in well-ventilated area.

• 

Never spray a flammable  
chemical (with a flash point  
less than 140°F [60°C]).

• 

Do not plug or unplug power 
cords or turn lights on or off when 
flammable fumes are present.

• 

Keep spray area free of debris, 
including solvents, rags,  
gasoline or any flammable  
chemicals.

• 

Keep a working fire extinguisher 
in the work area.

ENGLISH  |  3

BYOPLANET.COM

• 

Read and fully understand the ByoPlanet

®

 MS-700™ 

Electrostatic Sprayer Operator’s Manual prior to using 
the electrostatic sprayer.

• 

Read and fully understand ByoPlanet-approved  
product labels prior to using any liquid product with 
the ByoPlanet

®

 MS-700™ Electrostatic Sprayer.

• 

ByoPlanet

®

 MS-700™ Electrostatic Sprayers are for 

both indoor and outdoor commercial use. Bystanders 
and pets should not be in the area during application.

• 

ByoPlanet

®

 MS-700™ Electrostatic Sprayers should 

not be operated below 55°F (12.5°C).

• 

ByoPlanet

®

 MS-700™ Electrostatic Sprayers should 

never be used in any area containing volatile  
chemicals, nor should they be used in hazardous  
environments or any area containing volatile or  
explosive levels of gas, vapor or airborne particles.

• 

ByoPlanet

®

 MS-700™ Electrostatic Sprayers should 

never be used by untrained personnel.

• 

Check hoses, tubes  
and couplings daily.  
Replace worn or  
damaged parts  
immediately.

PRESSURIZED EQUIPMENT HAZARD 

Fluid from equipment that leaks or ruptures from a  
component can splash in the eyes or on skin, causing  
serious injury. In order to help prevent a leak or rupture:

Summary of Contents for MS-700

Page 1: ...ByoPlanet com OPERATOR S MANUAL For Indoor and Outdoor Commercial Use For service and support contact www ServiceTechTeam com Operator s Manual ENGLISH 2 11...

Page 2: ...TEM COMPONENTS MS 700 Electrostatic Sprayer Base Unit 7 MS 700 Electrostatic Sprayer 7 OPERATING INSTRUCTIONS Preparing the Spray Area 8 Unit Operation Setup 8 Sprayer Operation During Cleaning 8 Chan...

Page 3: ...is manual Stop operation immediately if static sparking occurs or you feel shock Do not use equipment until you identify and correct the problem Use and clean equipment only in well ventilated area Ne...

Page 4: ...e equipment when in the work area to help prevent serious injury Refer to product specific ByoPlanet Safety Data Sheets SDS for any additional Personal Protective Equipment PPE EQUIPMENT MISUSE HAZARD...

Page 5: ...resistance for an electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equip ment grounding conductor and a grounding plug The plug must be plugged in...

Page 6: ...ever hang unit from cord 12 A sprayer should never be left unattended when plugged in 13 A resettable breaker is provided on the rear of the unit It will trip if the unit experiences an electrical sho...

Page 7: ...e Handle Handle position is raised lowered and rotated by the two button snaps 8 Peristaltic Pump Provides liquid up to sprayer 9 Circuit Breaker User resettable circuit breaker and will only trip if...

Page 8: ...w areas moving the sprayer in a sweeping motion until surfaces are thoroughly wet Optimal spray distance away from surface is 2 4 feet 0 6 1 2 meters 15 After spraying keep the area closed to the publ...

Page 9: ...rom the device 2 When not in use ensure the device is powered off and unplug the power cord from the wall outlet and device 3 Wipe exterior surfaces of the device including hose and nozzle with a slig...

Page 10: ...penings and clear dislodge Flip the power switch back to the ON posi tion If the problem persists the user should let the unit sit for 30 minutes to see if it s an overheat ing issue If the unit still...

Page 11: ...chteam com to request replacement parts If unit has been stored without use for extended period of time peristaltic pump may not operate properly upon startup The user should run the unit for 5 minute...

Page 12: ...220 0550 FOR CUSTOMER COLLATERAL INCLUDING OPERATOR S MANUAL AND QUICK START GUIDES SERVICETECHTEAM COM 1 877 220 0550 QUESTIONS SERVICETECHTEAM COM CONTACT US FOR DEVICE WARRANTY INFORMATION SERVICE...